Installation of the Emergency Overwing Lights
TASK 33-51-15-400-001-A
Installation of the Emergency Overwing Lights
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 33-51-15-910-050-A ** ON A/C NOT FOR ALL
Subtask 33-51-15-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:57:27 UTC
Installation of the Emergency Overwing Lights
FIN: 60WL ** ON A/C NOT FOR ALL
FIN: 61WL ** ON A/C NOT FOR ALL
FIN: 62WL ** ON A/C NOT FOR ALL
FIN: 63WL ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 61WL ** ON A/C NOT FOR ALL
FIN: 62WL ** ON A/C NOT FOR ALL
FIN: 63WL ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE TO CLEAR EPSU FAILURE MESSAGES. THE TEACH-IN PROCEDURE IS NOT A SYSTEM RESET. IT CAN CHANGE THE EMERGENCY LIGHT CONFIGURATION AND CAUSE HIDDEN FAILURES.
NOTE: The teach-in procedure of the EPSUs measures and keeps the load values that are related to each EPSU. The EPSU controller refers to these load values when the BITE test of the emergency lighting system operates. Thus, it is necessary that the emergency lights of the related EPSUs operate correctly during the teach-in procedure.
Subtask 33-51-15-860-052-A ** ON A/C NOT FOR ALL A. Aircraft Maintenance Configuration
(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT EMER pushbutton switch and its integral light are off.
Subtask 33-51-15-860-052-E ** ON A/C NOT FOR ALL (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2) On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT EMER pushbutton switch and its integral light are off.
A. Aircraft Maintenance Configuration
(1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER button and its light are off.
Subtask 33-51-15-865-054-A ** ON A/C NOT FOR ALL (1) On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2) On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER button and its light are off.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H06 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H04 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/CABIN/EMER/LT | 3WL | V07 |
Subtask 33-51-15-910-050-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-15-420-050-A ** ON A/C NOT FOR ALL (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Emergency Overwing Light
(1) Installation of the Emergency Overwing-Light Assembly
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(c) Connect the electrical connector (1).
(d) Make sure that the work area is clean and clear of tools and other items.
(e) Put the emergency overwing-light assembly into position in the fuselage structure.
(f) Install the screws (2).
(2) Installation of the Bulb(s) of the Emergency Overwing Light
(a) Install the bulb(s) (7) in the light housing (8).
(b) Install the lens diffuser (6) in the light housing (8).
(c) Install the lens (4) and the sealing (5) with the screws (3) on the light housing (8).
Subtask 33-51-15-865-051-A ** ON A/C NOT FOR ALL (1) Installation of the Emergency Overwing-Light Assembly
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(b) Make sure that all the electrical connections are clean and in the correct condition.(c) Connect the electrical connector (1).
(d) Make sure that the work area is clean and clear of tools and other items.
(e) Put the emergency overwing-light assembly into position in the fuselage structure.
(f) Install the screws (2).
(2) Installation of the Bulb(s) of the Emergency Overwing Light
(a) Install the bulb(s) (7) in the light housing (8).
(b) Install the lens diffuser (6) in the light housing (8).
(c) Install the lens (4) and the sealing (5) with the screws (3) on the light housing (8).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-51-15-860-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H06 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CABIN | 2WL | H04 |
| 49VU | LIGHTING/EMER LT/CABIN | 1WL | H03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/CABIN/EMER/LT | 3WL | V07 |
D. Preparation for the Test
Subtask 33-51-15-710-053-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002). E. Do this test.
5. Close-up| ACTION | RESULT |
|---|---|
| 1.At the emergency exits: | At the emergency exits: |
|
|
|
|
| | On the overwing fuselage: |
| |
|
| 2.At the emergency exits: | At the emergency exits: |
|
|
| | On the overwing fuselage: |
| |
|
| 3.At the emergency exits: | At the emergency exits: |
|
|
Subtask 33-51-15-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Remove the wing mats.
(2) Remove the access platform(s).
Subtask 33-51-15-862-052-A ** ON A/C NOT FOR ALL (1) Remove the wing mats.
(2) Remove the access platform(s).
Emergency Overwing Light 60WL/61WL/62WL/63WL