W DOC AIRBUS | AMM A320F

BITE Check of the Emergency Power Supply Units (EPSU)


TASK 33-51-00-740-801-A
BITE Check of the Emergency Power Supply Units (EPSU)


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-00-861-001-A
Energize the Cabin Intercommunication Data System (CIDS)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-003-A
Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page
3. Job Set-up
Subtask 33-51-00-860-088-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Get access to the SYSTEM/REPORT/TEST COM Page (Ref. AMM TASK 31-32-00-860-003).
   (3) Make sure that the Cabin Intercommunication Data System (CIDS) is energized (Ref. AMM TASK 23-73-00-861-001).
   (4) In the cabin, on Forward Attendant Panel (FAP) 120RH, make sure that the EMER pushbutton switch is released (the position out/indicator light is off).
   (5) In the cockpit, on overhead panel 25VU, make sure that:
  • Switch 4WL EMER EXIT LT is in the OFF position
  • Switch 190RH NO SMOKING is in the OFF position
  • Indicator 5WL EMER EXIT LT OFF is ON.
Subtask 33-51-00-860-088-D ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Get access to the SYSTEM/REPORT/TEST COM Page (Ref. AMM TASK 31-32-00-860-003).
   (3) Make sure that the Cabin Intercommunication Data System (CIDS) is energized (Ref. AMM TASK 23-73-00-861-001).
   (4) In the cabin, on Forward Attendant Panel (FAP) 120RH, make sure that the EMER pushbutton switch is released (the position out/indicator light is off).
   (5) In the cockpit, on overhead panel 25VU, make sure that:
  • Switch 4WL EMER EXIT LT is in the OFF position
  • Switch 190RH NO SMOKING is in the OFF position
  • Indicator 5WL EMER EXIT LT OFF is ON.
Subtask 33-51-00-860-088-F ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the procedure to get access to the SYSTEM/REPORT/TEST COM Page (Ref. AMM TASK 31-32-00-860-003).
   (3) Make sure that the Cabin Intercommunication Data System (CIDS) is energized (Ref. AMM TASK 23-73-00-861-001).
   (4) In the cabin, on Flight Attendant Panel (FAP) 120RH, make sure that the EMER pushbutton switch is released (the position out/indicator light is off).
   (5) In the cockpit, on overhead panel 25VU, make sure that:
  • EMER EXIT LT switch 4WL is in the OFF position.
  • No PED switch 190RH is in the OFF position.
  • EMER EXIT LT OFF indicator 5WL is ON.
Subtask 33-51-00-861-067-A
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Energize the Cabin Intercommunication Data System (CIDS) (Ref. AMM TASK 23-73-00-861-001).
Subtask 33-51-00-865-075-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VULIGHTING/EMER LT/CABIN2WLH06
49VULIGHTING/EMER LT/CABIN1WLH05
122VULIGHTING/CABIN/EMER/LT3WLV07
4. Procedure
Subtask 33-51-00-740-052-A
A. BITE Check of the Emergency Power Supply Units (EPSUs)
   (1) Do this test:
ACTION
RESULT
1.In the cockpit, on the MCDU:
In the cockpit, on the MCDU:
  • Push line select key
    CIDS 1.
  • Menu page CIDS 1
    comes into view.
  • Push the line select key
    SYSTEM TESTS.
  • The menu page
    SYSTEM TESTS comes into view.
  • Push the line select key
    EPSU SYS TEST.
  • The menu page
    EPSU SYS TEST comes into view.
  • Push the line select key
    START TEST.
  • The system test starts and
    the message TEST IN PROGRESS 60S comes into view, then
    the message TEST OK comes into view.
  • Push the line select key
    RETURN until the menu page
    SYSTEM REPORT/TEST comes into view.
5. Close-up
Subtask 33-51-00-862-066-A
A. Put the aircraft back to the serviceable condition.
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.8 from Aug 2017] 2026.04.01 00:57:17 UTC