Removal of the Power Supply Unit of the Tail Cone Strobe-Light
TASK 33-48-39-000-001-A
Removal of the Power Supply Unit of the Tail Cone Strobe-Light
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 33-48-39-861-050-A Subtask 33-48-39-865-053-A
Subtask 33-48-39-020-050-A
[Rev.10 from 2021]
2026.04.01 00:56:48 UTC
Removal of the Power Supply Unit of the Tail Cone Strobe-Light
FIN: 18LV
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
Subtask 33-48-39-861-050-A Subtask 33-48-39-865-053-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-48-39-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the access door 314AR at Zone 310.
(2) Be careful not to step on a closed access door.
(3) Open access door 314AR and safety it in the open position.
(4) Set the light switch to on.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the access door 314AR at Zone 310.
(2) Be careful not to step on a closed access door.
(3) Open access door 314AR and safety it in the open position.
(4) Set the light switch to on.
Subtask 33-48-39-020-050-A
A. Removal of the Power Supply Unit (18LV)
(1) Disconnect the electrical connectors (4) and (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screws (2) and the washers (3).
(4) Remove the power supply unit (1).
(1) Disconnect the electrical connectors (4) and (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the screws (2) and the washers (3).
(4) Remove the power supply unit (1).
Power Supply Unit