Removal of the Power Supply Unit
TASK 33-48-38-000-001-A
Removal of the Power Supply Unit
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-48-38-941-052-A
Subtask 33-48-38-020-050-A
[Rev.10 from 2021]
2026.04.01 00:56:45 UTC
Removal of the Power Supply Unit
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [14LV] (PSU) | |
| 634AB | |
| FOR [15LV] (PSU) | |
| 534AB | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 33-48-38-941-052-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in position on panel 25VU to tell persons not to operate the strobe lights or the navigation lights.
Subtask 33-48-38-865-050-A (1) Put the SAFETY BARRIER(S) in position.
(2) Put a WARNING NOTICE(S) in position on panel 25VU to tell persons not to operate the strobe lights or the navigation lights.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-48-38-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel 534AB(634AB).
(2) Remove the applicable access panel:
(a) FOR [15LV] (PSU)
remove 534AB.
(b) FOR [14LV] (PSU)
remove 634AB.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel 534AB(634AB).
(2) Remove the applicable access panel:
(a) FOR [15LV] (PSU)
remove 534AB.
(b) FOR [14LV] (PSU)
remove 634AB.
Subtask 33-48-38-020-050-A
A. Removal of the Power Supply Unit
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the bolts (3) and the washers (2).
WARNING:
DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2 MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.
(1) Disconnect the electrical connectors (1) from the power supply unit (4). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the bolts (3) and the washers (2).
NOTE: The power supply unit has two location pins. They engage in the location pin sockets of the wing tip.
(4) Carefully remove the power supply unit (4).
Power Supply Unit