Removal of the Strobe Light Flash-Tube Assembly
TASK 33-48-14-000-002-A
Removal of the Strobe Light Flash-Tube Assembly
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 33-48-14-941-052-A ** ON A/C NOT FOR ALL
Subtask 33-48-14-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:56:37 UTC
Removal of the Strobe Light Flash-Tube Assembly
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER OPERATION. THE STROBE LIGHT WILL STILL BE HOT.
WARNING:
DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-37-12-000-802-A | Removal of the Navigation-Light Glazing Panel |
Subtask 33-48-14-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put a WARNING NOTICE(S) on panel 25VU to tell persons not to operate the strobe lights or the navigation lights.
(2) Put the SAFETY BARRIER(S) in position.
Subtask 33-48-14-865-055-A ** ON A/C NOT FOR ALL (1) Put a WARNING NOTICE(S) on panel 25VU to tell persons not to operate the strobe lights or the navigation lights.
(2) Put the SAFETY BARRIER(S) in position.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-48-14-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
C. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position under the applicable wing-tip strobe light in zone 534 or 634.
(2) Remove the glazing panel (1) from the applicable wing-tip strobe light (Ref. AMM TASK 57-37-12-000-802).
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position under the applicable wing-tip strobe light in zone 534 or 634.
(2) Remove the glazing panel (1) from the applicable wing-tip strobe light (Ref. AMM TASK 57-37-12-000-802).
Subtask 33-48-14-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Strobe Light Flash-Tube Assembly
(2) Remove the screws (5) and carefully remove the flash tube assembly (6).
CAUTION:
BE CAREFULL WHEN YOU REMOVE THE ATTACHMENT SCREWS. THE LENS CAN FALL OUT.
(1) Remove the screws (2), the lens (3) and the gasket (4). (2) Remove the screws (5) and carefully remove the flash tube assembly (6).
Strobe Light Flash Tube Assembly