W DOC AIRBUS | AMM A320F

Installation of the Flash Tube Assembly of the Upper Beacon/Strobe Light


TASK 33-48-11-400-003-A
Installation of the Flash Tube Assembly of the Upper Beacon/Strobe Light


WARNING: ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE ENVIRONMENT.
WARNING: DO NOT TOUCH THE STROBE LIGHTS FOR AT LEAST 5 MINUTES AFTER OPERATION. THE STROBE LIGHT WILL STILL BE HOT.
WARNING: DO NOT REMOVE THE STROBE LIGHT FOR AT LEAST TEN MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS. THE HIGH VOLTAGE ELECTRICAL CURRENT IN THE CAPACITOR OF THE STROBE LIGHT IS DANGEROUS.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 240
FIN: 7LV ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05BAA1)
Threadlocking Adhesive-- Low strength -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
240
MID PASSENGER COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 33-48-00-710-001-A
Operational Test of the Anti-Collision Lighting
TASK 33-48-11-400-001-A
Installation of the Upper Beacon/Strobe Light from the Outside of the Fuselage
TASK 33-48-11-400-002-A
Installation of the Upper Beacon/Strobe Light from the Inside of the Fuselage
3. Job Set-up
Subtask 33-48-11-861-050-A ** ON A/C NOT FOR ALL
A. Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-48-11-941-054-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the WARNING NOTICE(S) is in position on panel 25VU to tell persons not to operate the strobe lights or the navigation lights.
Subtask 33-48-11-860-056-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 33-48-11-865-060-A ** ON A/C NOT FOR ALL
D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VULIGHTING/EXT LT/BEACON/UPPER1LVU06
Subtask 33-48-11-010-059-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Make sure that switch 2LV BEACON ON-OFF on overhead panel 25VU is in the OFF position.
4. Procedure
Subtask 33-48-11-420-054-A ** ON A/C NOT FOR ALL
A. Installation of the Flash Tube Assembly of the Upper Beacon/Strobe Light
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Install the flash tube assembly (5) on the housing (2) of the upper beacon/strobe light as follows:
     (a) Carefully install the electrical connectors (4) in the hole of the housing (2) of the upper beacon/strobe light.
     (b) Put the flash tube assembly (5) in its correct installation position on the housing (2) of the upper beacon/strobe light.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (5) Connect the electrical connectors (4) on the transformer (3).
   (6) Apply Threadlocking Adhesive-- Low strength - (Material No.05BAA1) to the threads of the screws (1).
   (7) Install the screws (1) and tighten them.
Subtask 33-48-11-420-054-GL ** ON A/C NOT FOR ALL
A. Installation of the Flash Tube Assembly of the Upper Beacon/Strobe Light
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Install the flash tube assembly (7) on the plate (2) of the upper beacon/strobe light as follows:
     (a) Carefully install the electrical connectors (6) in the hole of the plate (2) of the upper beacon/strobe light.
     (b) Put the flash tube assembly (7) in its correct installation position on the plate (2) of the upper beacon/strobe light.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (5) Connect the electrical connectors (6) to the transformer (5).
   (6) Install the transformer (5) in the housing (3).
   (7) Install the screws (4) on the housing (3).
   (8) Tighten the screws (4).
   (9) Install the faraday cage (8) on the plate (2) of the upper beacon/strobe light.
   (10) Install the housing (3) on the plate (2) of the upper beacon/strobe light.
   (11) Install the screws (1) on the faraday cage (8).
   (12) Tighten the screws (1).
Subtask 33-48-11-410-057-A ** ON A/C NOT FOR ALL
B. Installation of the Upper Beacon/Strobe Light
   (1) Install the upper beacon/strobe light (Ref. AMM TASK 33-48-11-400-001) or (Ref. AMM TASK 33-48-11-400-002).
Subtask 33-48-11-865-061-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VULIGHTING/EXT LT/BEACON/UPPER1LVU06
Subtask 33-48-11-710-053-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do the operational test of the upper beacon/strobe light (7LV) (Ref. AMM TASK 33-48-00-710-001).
5. Close-up
Subtask 33-48-11-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 33-48-11-862-056-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:56:26 UTC