Replacement of the Halogen Bulb of the Landing Light
TASK 33-42-11-960-001-A
Replacement of the Halogen Bulb of the Landing Light
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 33-42-11-941-057-A
Subtask 33-42-11-210-060-A
Subtask 33-42-11-860-054-A
[Rev.9 from 2019]
2026.04.01 00:55:25 UTC
Replacement of the Halogen Bulb of the Landing Light
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
WARNING:
MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
WHEN YOU REPLACE A LANDING LIGHT BULB, EXAMINE THE APPLICABLE LANDING LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND FUEL CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL LEAKAGE:
1. Reason for the Job- THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
- THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING LIGHT ASSEMBLY.
- THE LEAK IS REPAIRED.
- THE LANDING LIGHT ASSEMBLY IS REPLACED.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.08BBD1) | Non Aqueous Cleaner-- Isopropyl Alcohol - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 571 | MLG BAY |
| 671 | MLG BAY |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | BULB | AIPC 33-46-11-02-050 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-11-00-280-002-A | Structural Fuel Tank Leaks - General Information |
| TASK 28-11-41-000-003-A | Removal of the Water Drain Valve |
| TASK 28-21-51-000-001-A | Removal of the Fuel Pumps |
| TASK 33-42-00-710-001-A | Operational Test of the Landing Lights |
Subtask 33-42-11-941-057-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the landing lights.
Subtask 33-42-11-010-052-A (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the landing lights.
B. Get Access
(1) Put an ACCESS PLATFORM 1M(3 FT) below the applicable landing light, zone 571 (671).
Subtask 33-42-11-860-056-A (1) Put an ACCESS PLATFORM 1M(3 FT) below the applicable landing light, zone 571 (671).
C. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Extend the landing light:
(a) In zone 571 (671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the lighting panel 25VU, set the LAND L (R) switch to OFF.
(c) Make sure the landing light extends.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 33-42-11-865-059-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Extend the landing light:
(a) In zone 571 (671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the lighting panel 25VU, set the LAND L (R) switch to OFF.
(c) Make sure the landing light extends.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/LANDING LT/R/CTL | 4LB | T07 |
| 122VU | LIGHTING/LANDING LT/R/SPLY | 2LB | T06 |
| 122VU | LIGHTING/LANDING LT/L/CTL | 3LB | T05 |
| 122VU | LIGHTING/LANDING LT/L/SPLY | 1LB | T04 |
Subtask 33-42-11-210-060-A
A. Examine the Landing Light Assembly for Fuel Contamination
(1) Examine the landing light assembly for signs of fuel contamination.
(2) If you find fuel contamination, examine the items that follow for fuel leakage:
Subtask 33-42-11-020-053-A (1) Examine the landing light assembly for signs of fuel contamination.
(2) If you find fuel contamination, examine the items that follow for fuel leakage:
- the fuel pumps 21QA(26QA) and 25QA(22QA) (Ref. AMM TASK 28-21-51-000-001)
- the water drain valve 25QM(26QM) (Ref. AMM TASK 28-11-41-000-003)
- the wing tank structure (Ref. AMM TASK 28-11-00-280-002).
B. Removal of the Halogen Bulb
(2) Remove the clamp (6).
(3) Pull the lens (7) away from the mirror (2).
(5) Carefully remove and discard the halogen bulb (3).
Subtask 33-42-11-420-054-A WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT- FREE CLOTH. IF NECESSARY, MAKE THE CLOTH MOIST WITH WATER. DRY WITH LOW-PRESSURE COMPRESSED AIR JET. DO NOT USE ALCOHOL.
CAUTION:
USE ONLY CLEAN, LINT-FREE GLOVES WHEN YOU TOUCH THE BULB AND THE MIRROR.
(1) Loosen the screw (5). (2) Remove the clamp (6).
(3) Pull the lens (7) away from the mirror (2).
NOTE: Put adhesive tape to hold the mirror (2) in position on the lamp housing (1).
(4) Remove the two screws (8) and the two washers (9). (5) Carefully remove and discard the halogen bulb (3).
C. Preparation for Installation
(1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the component interface and/or the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 33-42-11-420-056-A (1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the component interface and/or the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
D. Installation of the Halogen Bulb
(a) Tighten the two screws (8) carefully until they touch the halogen bulb (3) attachment brackets.
(b) Apply one more quarter turn to the two screws (8).
(3) Remove the adhesive tape from the mirror (2).
(4) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the component interface and/or the adjacent area.
(5) Clean the surface of the lens (7) with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) made moist with warm soap solution.
(6) Dry the surface of the lens (7) with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
(7) Put the lens (7) in position on the mirror (2).
(8) Put the clamp (6) in position.
(11) The distance between the two clamp (6) tabs is 10 mm (0.3937 in.) +/- 0.2 mm (0.0079 in.).
Subtask 33-42-11-865-060-A WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT- FREE CLOTH. IF NECESSARY, MAKE THE CLOTH MOIST WITH WATER. DRY WITH LOW-PRESSURE COMPRESSED AIR JET. DO NOT USE ALCOHOL.
CAUTION:
USE ONLY CLEAN, LINT-FREE GLOVES WHEN YOU TOUCH THE BULB AND THE MIRROR.
CAUTION:
USE ONLY THE SUPPLIED HANDLING TOOL TO INSTALL THE BULB. RETAIN THE HANDLING TOOL AFTER BULB INSTALLATION.
(1) Carefully put a new halogen AIPC 33-46-11-02-050 BULB (3) in position. NOTE: Make sure that the pinched seal (4) end points forward.
(2) Install the two washers (9) and the two screws (8). (a) Tighten the two screws (8) carefully until they touch the halogen bulb (3) attachment brackets.
(b) Apply one more quarter turn to the two screws (8).
(3) Remove the adhesive tape from the mirror (2).
(4) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the component interface and/or the adjacent area.
(5) Clean the surface of the lens (7) with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) made moist with warm soap solution.
(6) Dry the surface of the lens (7) with a clean Textile-Lint free Cotton - (Material No.14SBA1) .
(7) Put the lens (7) in position on the mirror (2).
(8) Put the clamp (6) in position.
NOTE: Examine the clamp (6). If it is twisted, replace it.
(9) Install the screw (5). CAUTION:
DO NOT USE THE BULB HANDLING TOOL TO TIGHTEN THE CLAMP SCREW. DAMAGE CAN OCCUR TO THE COMPONENTS IF THE BULB HANDLING TOOL BREAKS.
USE THE CORRECT TOOL TO TIGHTEN THE CLAMP SCREW.
(10) Tighten the screw (5) until the screw head touches the clamp tab. (11) The distance between the two clamp (6) tabs is 10 mm (0.3937 in.) +/- 0.2 mm (0.0079 in.).
NOTE: You can use the bulb handling tool gage to measure the distance between the clamp tabs.
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-42-11-710-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/LANDING LT/R/CTL | 4LB | T07 |
| 122VU | LIGHTING/LANDING LT/R/SPLY | 2LB | T06 |
| 122VU | LIGHTING/LANDING LT/L/CTL | 3LB | T05 |
| 122VU | LIGHTING/LANDING LT/L/SPLY | 1LB | T04 |
F. Operational Test
(1) Do the operational test of the landing light (Ref. AMM TASK 33-42-00-710-001).
5. Close-up(1) Do the operational test of the landing light (Ref. AMM TASK 33-42-00-710-001).
Subtask 33-42-11-860-054-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Retract the landing light:
(a) In zone 571 (671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the lighting panel 25VU, set the LAND L (R) switch to RETRACT.
(c) Make sure the landing light retracts.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 33-42-11-942-053-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Retract the landing light:
(a) In zone 571 (671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the lighting panel 25VU, set the LAND L (R) switch to RETRACT.
(c) Make sure the landing light retracts.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
B. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Halogen Bulb of the Landing Light - Location and Details