Installation of the Landing Light Lamp
TASK 33-42-11-400-004-A
Installation of the Landing Light Lamp
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 33-42-11-941-056-A
Subtask 33-42-11-420-053-A
Subtask 33-42-11-860-053-A
[Rev.10 from 2021]
2026.04.01 00:55:23 UTC
Installation of the Landing Light Lamp
WARNING:
MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
WARNING:
MAKE SURE THAT THERE ARE NO SIGNS OF FUEL CONTAMINATION IN THE LANDING LIGHT ASSEMBLY.
IF YOU FIND FUEL CONTAMINATION, NO PERSON MUST OPERATE THE LANDING LIGHT UNTIL:
- YOU REPAIR THE FUEL LEAK
- YOU REPLACE THE LANDING LIGHT ASSEMBLY.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
WHEN YOU REPLACE A LANDING LIGHT LAMP, EXAMINE THE APPLICABLE LANDING LIGHT ASSEMBLY FOR SIGNS OF FUEL CONTAMINATION. IF YOU FIND FUEL CONTAMINATION, EXAMINE THE ITEMS THAT FOLLOW FOR SIGNS OF FUEL LEAKAGE:
1. Reason for the Job- THE FUEL PUMP(S) 21QA(26QA) OR 25QA(22QA)
- THE WATER DRAIN VALVE 25QM(26QM) DIRECTLY FORWARD OF THE LANDING LIGHT ASSEMBLY.
- THE LEAK IS REPAIRED
- THE LANDING LIGHT ASSEMBLY IS REPLACED.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 5 | CLAMP | AIPC 33-42-11-01-020 |
| 6 | CLAMP | AIPC 33-42-11-01-020 |
| 2 | SEAL | AIPC 33-42-11-01-040 |
| 4 | SEAL | AIPC 33-42-11-01-040 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 33-42-00-710-001-A | Operational Test of the Landing Lights |
Subtask 33-42-11-941-056-A
A. Safety Precautions
(1) Make sure that the SAFETY BARRIER(S) are in position.
(2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the landing lights.
Subtask 33-42-11-860-052-A (1) Make sure that the SAFETY BARRIER(S) are in position.
(2) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the landing lights.
B. Aircraft Maintenance Configuration
(1) Make sure that the landing light is in the extended position.
(2) In the cockpit, on the EXT LT section of panel 25VU, make sure that the LAND L(R) switch is set to OFF.
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position below the applicable landing light.
Subtask 33-42-11-865-056-A (1) Make sure that the landing light is in the extended position.
(2) In the cockpit, on the EXT LT section of panel 25VU, make sure that the LAND L(R) switch is set to OFF.
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position below the applicable landing light.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/LANDING LT/R/CTL | 4LB | T07 |
| 122VU | LIGHTING/LANDING LT/R/SPLY | 2LB | T06 |
| 122VU | LIGHTING/LANDING LT/L/CTL | 3LB | T05 |
| 122VU | LIGHTING/LANDING LT/L/SPLY | 1LB | T04 |
Subtask 33-42-11-420-053-A
A. Preparation for the Installation
(1) For the General Electric (GE) sealed-beam landing-light lamp, do these steps:
(a) Clean the component interface and/or the adjacent area with the clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Do an inspection of the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Make sure that the two electrical terminals (3) and the GE sealed-beam landing-light lamp terminals are clean and in the correct condition.
(e) Remove all the corrosion and the lacquer from the GE sealed-beam landing-light lamp (7) to make sure that there is a good electrical connection.
(2) For the LED landing light-lamp, do these steps:
(a) Clean the component interface and/or the adjacent area with the clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Do an inspection of the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Make sure that the electrical terminals and the LED landing light-lamp terminals are clean and in the correct condition.
(e) Remove all the corrosion and the lacquer from the LED landing light-lamp (3) to make sure that there is a good electrical connection.
Subtask 33-42-11-420-051-A (1) For the General Electric (GE) sealed-beam landing-light lamp, do these steps:
(a) Clean the component interface and/or the adjacent area with the clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Do an inspection of the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Make sure that the two electrical terminals (3) and the GE sealed-beam landing-light lamp terminals are clean and in the correct condition.
(e) Remove all the corrosion and the lacquer from the GE sealed-beam landing-light lamp (7) to make sure that there is a good electrical connection.
(2) For the LED landing light-lamp, do these steps:
(a) Clean the component interface and/or the adjacent area with the clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(b) Do an inspection of the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Make sure that the electrical terminals and the LED landing light-lamp terminals are clean and in the correct condition.
(e) Remove all the corrosion and the lacquer from the LED landing light-lamp (3) to make sure that there is a good electrical connection.
B.
(a) If necessary, install the new AIPC 33-42-11-01-040 SEAL (4) on the lamp housing (1).
(b) Connect the two electrical terminals (3) to the GE sealed-beam landing-light lamp (7) with the screws (2).
(c) Tighten the screws (2).
(d) Install the GE sealed-beam landing-light lamp (7) in the lamp housing (1).
(e) Make sure that the filament of the lamp is in the horizontal position (as shown on the filament position plate (8)).
(f) Put the clamp (6) in position.
(g) If necessary, install the new AIPC 33-42-11-01-020 CLAMP (6) with the screw (5).
(h) TORQUE the screw (5) to between 0.080 and 0.070 m.daN (7.08 and 6.19 lbf.in )
.
(a) If necessary, install the new AIPC 33-42-11-01-040 SEAL (2) on the lamp housing (1).
(b) Connect the electrical terminals to the LED landing light-lamp (3).
(c) Put the LED landing light-lamp (3) on the lamp housing (1).
(d) Make sure that the filament of the LED landing light-lamp (3) together with the line of the six collimators are in the horizontal position (as shown on the filament position plate (6)).
(e) Hold the LED landing light-lamp (3).
(f) Put the clamp (5) in position.
(g) If necessary, install the new AIPC 33-42-11-01-020 CLAMP (5) with the screw (4).
(h) TORQUE the screw (4) to between 0.080 and 0.070 m.daN (7.08 and 6.19 lbf.in )
.
Subtask 33-42-11-865-057-A WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT- FREE CLOTH. IF NECESSARY, MAKE THE CLOTH MOIST WITH WATER. DRY WITH LOW-PRESSURE COMPRESSED AIR JET. DO NOT USE ALCOHOL.
(1) For the GE sealed-beam landing-light lamp, do these steps: (a) If necessary, install the new AIPC 33-42-11-01-040 SEAL (4) on the lamp housing (1).
(b) Connect the two electrical terminals (3) to the GE sealed-beam landing-light lamp (7) with the screws (2).
(c) Tighten the screws (2).
(d) Install the GE sealed-beam landing-light lamp (7) in the lamp housing (1).
(e) Make sure that the filament of the lamp is in the horizontal position (as shown on the filament position plate (8)).
(f) Put the clamp (6) in position.
(g) If necessary, install the new AIPC 33-42-11-01-020 CLAMP (6) with the screw (5).
(h) TORQUE the screw (5) to between 0.080 and 0.070 m.daN (7.08 and 6.19 lbf.in )
. WARNING:
WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU DO WORK ON THE LIGHT. THE LAMP IS PRESSURIZED AND AN EXPLOSION CAN OCCUR.
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT- FREE CLOTH. IF NECESSARY, MAKE THE CLOTH MOIST WITH WATER. DRY WITH LOW-PRESSURE COMPRESSED AIR JET. DO NOT USE ALCOHOL.
(2) For the LED landing light-lamp, do these steps:(a) If necessary, install the new AIPC 33-42-11-01-040 SEAL (2) on the lamp housing (1).
(b) Connect the electrical terminals to the LED landing light-lamp (3).
(c) Put the LED landing light-lamp (3) on the lamp housing (1).
(d) Make sure that the filament of the LED landing light-lamp (3) together with the line of the six collimators are in the horizontal position (as shown on the filament position plate (6)).
(e) Hold the LED landing light-lamp (3).
(f) Put the clamp (5) in position.
(g) If necessary, install the new AIPC 33-42-11-01-020 CLAMP (5) with the screw (4).
(h) TORQUE the screw (4) to between 0.080 and 0.070 m.daN (7.08 and 6.19 lbf.in )
. C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-42-11-710-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/LANDING LT/R/CTL | 4LB | T07 |
| 122VU | LIGHTING/LANDING LT/R/SPLY | 2LB | T06 |
| 122VU | LIGHTING/LANDING LT/L/CTL | 3LB | T05 |
| 122VU | LIGHTING/LANDING LT/L/SPLY | 1LB | T04 |
D. Operational Test
(1) Do the operational test of the landing light (Ref. AMM TASK 33-42-00-710-001).
5. Close-up(1) Do the operational test of the landing light (Ref. AMM TASK 33-42-00-710-001).
Subtask 33-42-11-860-053-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Retract the landing light:
(a) At zone 571(671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the EXT LT section of panel 25VU, set the LAND L(R) switch to RETRACT.
(c) Make sure that the landing light retracts.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 33-42-11-942-051-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Retract the landing light:
(a) At zone 571(671), make sure that the travel range of the landing light is clear.
(b) In the cockpit, on the EXT LT section of panel 25VU, set the LAND L(R) switch to RETRACT.
(c) Make sure that the landing light retracts.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
B. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
GE landing-light lamp