W DOC AIRBUS | AMM A320F

Removal of the Lamp(s) of the MLG Dome Light (AIRSIGNA)


TASK 33-37-11-000-002-A
Removal of the Lamp(s) of the MLG Dome Light (AIRSIGNA)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
NOTE: The procedure is the same for all MLG dome lights (AIRSIGNA).
FIN: 10LL ** ON A/C NOT FOR ALL
FIN: 7LL
FIN: 8LL
FIN: 9LL ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
FOR [10LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [7LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [8LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [9LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10LL] (MAINTENANCE LIGHT)
196BB
FOR [9LL] (MAINTENANCE LIGHT)
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
F MLG Dome Light ** ON A/C NOT FOR ALL
FOR [7LL] (MAINTENANCE LIGHT)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
FOR [8LL] (MAINTENANCE LIGHT)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
3. Job Set-up
Subtask 33-37-11-865-053-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/WHL WELL/LTG/DOME2LLX08
Subtask 33-37-11-010-052-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the applicable access door/panel:
     (a) FOR [7LL] (MAINTENANCE LIGHT)
     (b) FOR [8LL] (MAINTENANCE LIGHT)
     (c) FOR [9LL] (MAINTENANCE LIGHT)
  • Open the access panel 195BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
     (d) FOR [10LL] (MAINTENANCE LIGHT)
  • Open the access panel 196BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.
Subtask 33-37-11-010-052-B
B. Get Access
   (1) Open the applicable access panel:
     (a) FOR [9LL] (MAINTENANCE LIGHT)
  • Open the access panel 195BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
     (b) FOR [10LL] (MAINTENANCE LIGHT)
  • Open the access panel 196BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.
4. Procedure
Subtask 33-37-11-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Lamp(s) of the MLG Dome Light
   (1) Loosen the captive screws (4) and remove the cover assembly (3).
NOTE: The lens is bonded in the cover assembly and cannot be replaced.
   (2) Remove the lamp(s) (2) from the light assembly (5) and discard the lamp(s).
[Rev.10 from 2021] 2026.04.01 00:54:42 UTC