W DOC AIRBUS | AMM A320F

Removal of the MLG Dome Light (HELLA)


TASK 33-37-11-000-001-A
Removal of the MLG Dome Light (HELLA)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
NOTE: The procedure is the same for all MLG dome lights (HELLA).
FIN: 10LL ** ON A/C NOT FOR ALL
FIN: 7LL ** ON A/C NOT FOR ALL
FIN: 8LL ** ON A/C NOT FOR ALL
FIN: 9LL ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
FOR [10LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [7LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [8LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
FOR [9LL] (MAINTENANCE LIGHT)
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10LL] (MAINTENANCE LIGHT)
196BB
FOR [9LL] (MAINTENANCE LIGHT)
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
F MLG Dome Light ** ON A/C NOT FOR ALL
F MLG Dome Light ** ON A/C NOT FOR ALL
FOR [7LL] (MAINTENANCE LIGHT)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
FOR [8LL] (MAINTENANCE LIGHT)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
3. Job Set-up
Subtask 33-37-11-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VULIGHTING/WHL WELL/LTG/DOME2LLX08
Subtask 33-37-11-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the applicable access door/panel:
     (a) FOR [7LL] (MAINTENANCE LIGHT)
     (b) FOR [8LL] (MAINTENANCE LIGHT)
     (c) FOR [9LL] (MAINTENANCE LIGHT)
  • Open the access panel 195BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 195.
     (d) FOR [10LL] (MAINTENANCE LIGHT)
  • Open the access panel 196BB.
  • Put the ACCESS PLATFORM 2M (6 FT) in position at zone 196.
Subtask 33-37-11-010-050-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the applicable access door:
     (a) FOR [7LL] (MAINTENANCE LIGHT)
     (b) FOR [8LL] (MAINTENANCE LIGHT)
4. Procedure
Subtask 33-37-11-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the MLG Dome Light
   (1) Find the MLG dome light.
   (2) Support the dome light (1).
   (3) Remove the screws (2) and the washers (3).
   (4) Remove the nuts (4) and the washers (5).
   (5) Remove the electrical connectors (6).
   (6) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (7) Remove the dome light (1).
[Rev.10 from 2021] 2026.04.01 00:54:40 UTC