Installation of the Lamp of the Service Area Light
TASK 33-31-11-400-004-A
Installation of the Lamp of the Service Area Light
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 33-31-11-865-073-A ** ON A/C NOT FOR ALL
Subtask 33-31-11-910-053-A ** ON A/C NOT FOR ALL
(2) Correctly align the cover assembly (4) with the screw holes of the housing (1).
(3) Install the captive screws (5) and tighten.
Subtask 33-31-11-865-077-A ** ON A/C NOT FOR ALL
Subtask 33-31-11-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:54:19 UTC
Installation of the Lamp of the Service Area Light
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06LCG9) | Non Hardening Jointing Putty-Medium Temp. Area - - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 33-31-00-710-001-A | Operational Test of the Service Area Lighting |
Subtask 33-31-11-865-073-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-31-11-860-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT-SEC19 | 1LJ | E07 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT/SEC19 | 1LJ | E07 |
B. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position below the access door at zone 312.
(2) Make sure that the access door 312AR is open.
(3) Make sure that the switch 3LJ at zone 312 is set to the OFF position.
4. Procedure(1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position below the access door at zone 312.
(2) Make sure that the access door 312AR is open.
(3) Make sure that the switch 3LJ at zone 312 is set to the OFF position.
Subtask 33-31-11-910-053-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Apply the Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the captive screws (5).
Subtask 33-31-11-420-054-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Apply the Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the captive screws (5).
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
B. Installation of the Lamp of the Service Area Light NOTE: When it is necessary to replace one lamp, it is recommended that you replace the second lamp at the same time.
(1) Put the lamp (3) in the light assembly (2) and turn it clockwise to lock the lamp in position. (2) Correctly align the cover assembly (4) with the screw holes of the housing (1).
(3) Install the captive screws (5) and tighten.
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-31-11-710-053-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT-SEC19 | 1LJ | E07 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT/SEC19 | 1LJ | E07 |
Subtask 33-31-11-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 312AR.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 312AR.
(3) Remove the access platform(s).
Service Area Light