W DOC AIRBUS | AMM A320F

Removal of the Service Area Light


TASK 33-31-11-000-002-A
Removal of the Service Area Light


FIN: 4LJ
FIN: 5LJ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
312AR
 C. Referenced Information
REFERENCE
DESIGNATION
F Service Area Light ** ON A/C NOT FOR ALL
F Service Area Light ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 33-31-11-865-068-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VULIGHT-SEC191LJE07
** ON A/C NOT FOR ALL
2001VULIGHT/SEC191LJE07
Subtask 33-31-11-010-051-A
B. Get Access
   (1) Put a warning notice in the cockpit to tell persons not to operate the flight controls.
   (2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position in the Zone 312.
   (3) Open the access door 312AR.
   (4) Set the switch 3LJ at Zone 312 to the OFF position.
4. Procedure
Subtask 33-31-11-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Service Area Light and the Lamp
   (1) Remove the lamp:
     (a) Remove the screws (12), the grid-screen (7), the lens (8) and the seal (9) from the housing (11).
     (b) Remove the lamp (10).
   (2) Remove the service area light:
     (a) Remove the screws (6), the washers (5) and hold the service area light (4) to get access to the electrical connections (1).
     (b) Remove the nuts (3), the washers (2) and the electrical connections (1).
     (c) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (d) Remove the service area light (4).
Subtask 33-31-11-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Service Area Light
   (1) Remove the screws (1) with the washers (2) and hold the service area light (3) to get access to the electrical connectors (5) an (6).
   (2) Disconnect the electrical connectors (5) and (6).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the service area light (3).
[Rev.10 from 2021] 2026.04.01 00:54:14 UTC