Functional Test of the Maintenance Sockets
TASK 33-31-00-720-001-A
Functional Test of the Maintenance Sockets
To make sure that the maintenance sockets operate correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-31-00-861-051-A Subtask 33-31-00-865-053-A
Subtask 33-31-00-860-050-A
Subtask 33-31-00-410-051-A
[Rev.10 from 2021]
2026.04.01 00:54:11 UTC
Functional Test of the Maintenance Sockets
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
1. Reason for the JobTo make sure that the maintenance sockets operate correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | MULTIMETER - STANDARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 314AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
| TASK 52-41-23-410-801-A | Closing of Access Door 314AR |
Subtask 33-31-00-861-051-A Subtask 33-31-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 33-31-00-010-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT-SEC19 | 1LJ | E07 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT/SEC19 | 1LJ | E07 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position in Zone 314.
(2) Open the access door 314AR (Ref. AMM TASK 52-41-23-010-801).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position in Zone 314.
(2) Open the access door 314AR (Ref. AMM TASK 52-41-23-010-801).
Subtask 33-31-00-860-050-A
A. Preparation for the Test.
(1) Use the MULTIMETER - STANDARD for this test.
Subtask 33-31-00-720-050-A (1) Use the MULTIMETER - STANDARD for this test.
B. Functional Test
(1) Do the functional test of the maintenance sockets:
5. Close-up(1) Do the functional test of the maintenance sockets:
| ACTION | RESULT |
|---|---|
| 1.In the section 19 service area: | On the multimeter: |
|
|
Subtask 33-31-00-410-051-A
A. Close Access
(1) Remove the multimeter.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(4) Remove the access platform(s).
Subtask 33-31-00-862-051-A (1) Remove the multimeter.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(4) Remove the access platform(s).