Operational Test of the Service Area Lighting
TASK 33-31-00-710-001-A
Operational Test of the Service Area Lighting
To make sure that the service area lighting operates correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-31-00-861-050-A Subtask 33-31-00-865-052-A
Subtask 33-31-00-710-050-A
Subtask 33-31-00-410-050-A
[Rev.10 from 2021]
2026.04.01 00:54:10 UTC
Operational Test of the Service Area Lighting
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
1. Reason for the JobTo make sure that the service area lighting operates correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4LJ] (MAINT. LIGHT) | |
| FOR [5LJ] (MAINT. LIGHT) | |
| 312AR | |
| FOR [6LJ] (MAINT. LIGHT) | |
| 315AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 33-31-00-861-050-A Subtask 33-31-00-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 33-31-00-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT-SEC19 | 1LJ | E07 |
| ** ON A/C ALL | |||
| 2001VU | LIGHT-APU | 2LJ | E08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LIGHT/SEC19 | 1LJ | E07 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
in Zone 312.
(b) FOR [6LJ] (MAINT. LIGHT)
below the APU compartment.
(2) Open the access door:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
open 312AR.
(b) FOR [6LJ] (MAINT. LIGHT)
open 315AL.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
in Zone 312.
(b) FOR [6LJ] (MAINT. LIGHT)
below the APU compartment.
(2) Open the access door:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
open 312AR.
(b) FOR [6LJ] (MAINT. LIGHT)
open 315AL.
Subtask 33-31-00-710-050-A
A. Test of the Service Area Lighting.
(1) Do this test.
5. Close-up(1) Do this test.
| ACTION | RESULT |
|---|---|
| 1.In the section 19 service area: | In the section 19 service area: |
|
|
|
|
| 2.In the APU compartment: | In the APU compartment: |
|
|
|
|
Subtask 33-31-00-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
close 312AR.
(b) FOR [6LJ] (MAINT. LIGHT)
close 315AL.
(3) Remove the access platform(s).
Subtask 33-31-00-862-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door:
(a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
close 312AR.
(b) FOR [6LJ] (MAINT. LIGHT)
close 315AL.