W DOC AIRBUS | AMM A320F

Installation of the Lavatory-Occupied Signs (WJ)


TASK 33-26-23-400-001-A
Installation of the Lavatory-Occupied Signs (WJ)


ZONE: 220
ZONE: 260
FIN: 13WJ
FIN: 14WJ ** ON A/C NOT FOR ALL
FIN: 23WJ ** ON A/C NOT FOR ALL
FIN: 25WJ ** ON A/C NOT FOR ALL
FIN: 3WJ
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
STEPLADDER 1.0 M (3.3 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
220
FWD CAB UTILITY AREAS
260
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 33-26-00-710-001-A
Operational Test of the Lavatory Lighted Signs WJ
3. Job Set-up
Subtask 33-26-23-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-OCCUPIED1WJF01
** ON A/C ALL
2001VULAVATORY AFT-OCCUPIED11WJB04
Subtask 33-26-23-941-052-A
B. Make sure that the STEPLADDER 1.0 M (3.3 FT) is in position below the lavatory-occupied sign.
4. Procedure
Subtask 33-26-23-420-050-B
A. Installation of the Lavatory-Occupied Sign
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (4) Connect the electrical connectors (4) to the sign housing (5).
   (5) Install the sign housing (5) with the washers (3) and the screws (2).
   (6) Install the lens (1) on the sign housing (5).
Make sure that you hear a click when the lens (1) locks in position.
Subtask 33-26-23-865-055-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-OCCUPIED1WJF01
** ON A/C ALL
2001VULAVATORY AFT-OCCUPIED11WJB04
Subtask 33-26-23-710-050-A
C. Operational Test
   (1) Do the test of the lavatory lighted signs (Ref. AMM TASK 33-26-00-710-001).
5. Close-up
Subtask 33-26-23-942-051-A
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the stepladder.
[Rev.10 from 2021] 2026.04.01 00:53:57 UTC