W DOC AIRBUS | AMM A320F

Installation of the Accent Mirror Light


TASK 33-24-12-400-804-A
Installation of the Accent Mirror Light


FIN: 62LQ111 ** ON A/C NOT FOR ALL
FIN: 62LQ112 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20
No specific
AR
TIE WRAP
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 33-24-00-710-001-A
Operational Test of the Lavatory Lighting LQ
TASK 33-24-12-000-803-A
Removal of the Accent Ceiling Light
TASK 33-24-12-000-805-A
Removal of the Accent Washtable Light
TASK 33-24-12-400-803-A
Installation of the Accent Ceiling Light
TASK 33-24-12-400-805-A
Installation of the Accent Washtable Light
3. Job Set-up
Subtask 33-24-12-860-058-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized
(Ref. AMM TASK 24-41-00-861-002).
   (2) In the SMART lavatory:
F Accent Mirror Light ** ON A/C NOT FOR ALL
     (a) FOR 62LQ*
       1 Make sure that the upper service panel (7) is open.
       2 Make sure that the service cabinet above the baby nursing table is open.
       3 Make sure that the cover of the ceiling light and the cover of the washtable light are removed (Ref. AMM TASK 33-24-12-000-803) (Ref. AMM TASK 33-24-12-000-805).
Subtask 33-24-12-865-065-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH07
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH05
** ON A/C NOT FOR ALL
2000VULAV FWD-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2000VULIGHT-LAV1LQJ01
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-OCCUPIED11WJB04
4. Procedure
Subtask 33-24-12-420-054-A ** ON A/C NOT FOR ALL
A. Install the Accent Mirror Light
F Accent Mirror Light ** ON A/C NOT FOR ALL
   (1) Put the accent mirror light (2) in position and push it until all clamps (4) engage.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (2) Connect the electrical contacts (1) to the terminal block (6), use the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20.
   (3) Install the brackets (12) with the washers (10) and the screws (9) and install the terminal block (6) on the lavatory wall.
   (4) Put the cable (11) in position and install the new TIE WRAP(S) (5).
   (5) Install the light cover (3).
Subtask 33-24-12-410-052-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Close Access to the Accent Mirror Light in the SMART lavatory:
F Accent Mirror Light ** ON A/C NOT FOR ALL
     (a) FOR 62LQ*
       1 Install the cover of the ceiling light and the cover of the washtable light (Ref. AMM TASK 33-24-12-400-803) (Ref. AMM TASK 33-24-12-400-805).
       2 Close the upper service panel (7) and tighten the two studs (8).
       3 Close the service cabinet above the baby nursing table.
Subtask 33-24-12-865-066-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH07
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN79WLH05
** ON A/C NOT FOR ALL
2000VULAV FWD-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2000VULIGHT-LAV1LQJ01
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-OCCUPIED1WJF01
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-OCCUPIED11WJB04
Subtask 33-24-12-710-054-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do the operational test of the lavatory lighting (Ref. AMM TASK 33-24-00-710-001).
5. Close-up
Subtask 33-24-12-860-059-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:53:42 UTC