Removal of the Essential Transformers
TASK 33-14-51-000-001-A
Removal of the Essential Transformers
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 33-14-51-865-050-A
Subtask 33-14-51-020-050-A
[Rev.10 from 2021]
2026.04.01 00:53:05 UTC
Removal of the Essential Transformers
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 33-14-51-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-14-51-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 31LP (XFMRESS) | |||
| 49VU | LIGHTING/XFMR/115V.5V/ESS BUS | 29LP | H03 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/XFMR/115V.5V/ESS BUS | 29LP | H01 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 35LP (XFMRESS) | |||
| 49VU | LIGHTING/XFMR/115V.5V/ESS BUS | 29LP | H03 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/XFMR/115V.5V/ESS BUS | 29LP | H01 |
| ** ON A/C ALL | |||
| 122VU | LIGHTING/ANN LT SPLY/XFMR/STAT INV | 28LP | X03 |
B. Get Access
(1) Remove the ceiling panel 211HC with an ALLEN wrench.
4. Procedure(1) Remove the ceiling panel 211HC with an ALLEN wrench.
Subtask 33-14-51-020-050-A
A. Removal of the Essential Transformer
(1) Disconnect the movable connector (4) from the defective transformer (1). Put a CAP - BLANKING on the disconnected connector.
(2) Loosen the four screws (3) and the washers (2) that attach the defective transformer (1) to the structure.
(3) Remove the defective transformer (1).
(1) Disconnect the movable connector (4) from the defective transformer (1). Put a CAP - BLANKING on the disconnected connector.
(2) Loosen the four screws (3) and the washers (2) that attach the defective transformer (1) to the structure.
(3) Remove the defective transformer (1).
Essential Transformer