Removal of the Annunciator-Light Test and Interface-Board
TASK 33-14-33-000-001-A
Removal of the Annunciator-Light Test and Interface-Board
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-14-33-865-050-A
Subtask 33-14-33-020-050-A
[Rev.10 from 2021]
2026.04.01 00:53:03 UTC
Removal of the Annunciator-Light Test and Interface-Board
CAUTION:
DURING REMOVAL AND INSTALLATION OF THE PRINTED CIRCUIT BOARDS (PCB'S) THAT HAVE THE ESD SYMBOL, OBEY THESE PRECAUTIONS:
- USE A CONDUCTIVE WRIST-STRAP THAT IS ELECTRICALLY GROUNDED (CONNECTED TO A BONDING-POINT NEAR THE WORK AREA) BEFORE AND DURING HANDLING OF THE PCB'S. IF NO WRIST-STRAP IS AVAILABLE, MAKE SURE THAT YOU ARE ELECTRICALLY CONNECTED TO THE AIRCRAFT GROUND BEFORE YOU HANDLE THE PCB'S.
- DO NOT TOUCH THE ELECTRICAL CONNECTOR PINS.
- PREVENT CONTACT WITH THE TOP FACE OR BOTTOM FACE OF THE PCB WHERE THE ELECTRONIC DEVICES ARE LOCATED.
- MAKE SURE THAT THE REPLACEMENT PCB'S ARE IN THEIR PROTECTIVE PACKAGING AND/OR NON-CONDUCTIVE BOX WHEN YOU RECEIVE THEM ON THE AIRCRAFT.
- MAKE SURE THAT YOU PUT THE DEFECTIVE (REMOVED) PCB'S IN PROTECTIVE WRAPS FOR TRANSPORT BACK TO THE HANGAR.
ZONE: 126
FIN: 1LP
FIN: 10LP
FIN: 11LP
FIN: 12LP
FIN: 18LP
FIN: 19LP
FIN: 2LP
FIN: 20LP
FIN: 3LP
FIN: 4LP
FIN: 5LP
FIN: 6LP
FIN: 7LP
FIN: 8LP
FIN: 9LP
1. Reason for the JobFIN: 1LP
FIN: 10LP
FIN: 11LP
FIN: 12LP
FIN: 18LP
FIN: 19LP
FIN: 2LP
FIN: 20LP
FIN: 3LP
FIN: 4LP
FIN: 5LP
FIN: 6LP
FIN: 7LP
FIN: 8LP
FIN: 9LP
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 126 | LATERAL AVIONIC COMPARTMENT |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 33-14-33-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 33-14-33-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the access door 822.
(2) Open the access door 822.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the access door 822.
(2) Open the access door 822.
Subtask 33-14-33-020-050-A
A. Removal of the board
(1) Fully loosen the two screws (2) that attach the defective annunciator-light test and interface-board (1) to its support (3).
(2) Remove the annunciator light test board (1).
(1) Fully loosen the two screws (2) that attach the defective annunciator-light test and interface-board (1) to its support (3).
(2) Remove the annunciator light test board (1).
Annunciator-Light Test and Interface-Board