W DOC AIRBUS | AMM A320F

Installation of the Rheostat - Flood Light


TASK 33-12-17-400-001-A
Installation of the Rheostat - Flood Light


ZONE: 211
ZONE: 212
FIN: 28LE ** ON A/C NOT FOR ALL
FIN: 35LE ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 B. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
9
RHEOSTAT
AIPC 33-12-08-02-130
20
RHEOSTAT
AIPC 33-12-08-02-140
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 33-12-00-710-001-A
Operational Test of the General Illumination
3. Job Set-up
Subtask 33-12-17-865-051-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CKPT/DOME1LEH08
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
4. Procedure
Subtask 33-12-17-420-050-A ** ON A/C NOT FOR ALL Subtask 33-12-17-420-051-A ** ON A/C NOT FOR ALL Subtask 33-12-17-865-052-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CKPT/DOME1LEH08
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
Subtask 33-12-17-710-050-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 33-12-17-942-050-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.