Removal of the Rheostat - Flood Light
TASK 33-12-17-000-001-A
Removal of the Rheostat - Flood Light
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-12-17-865-050-A ** ON A/C NOT FOR ALL
Subtask 33-12-17-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:52:39 UTC
Removal of the Rheostat - Flood Light
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 33-12-17-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CKPT/DOME | 1LE | H08 |
| 122VU | LIGHTING/FLOOD/CTR INST/PNL | 2LE | Z04 |
Subtask 33-12-17-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Pedestal Flood-Light Rheostat (28LE)
(1) Loosen the two fasteners (2).
(2) Carefully pull the panel 112VU (1).
(3) Remove the two screws (11) and disconnect the electrical connector (10).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (6) located on the knob (5), do not remove them.
(6) Remove the knob (5).
(7) Remove the two screws (4) and the placard (3).
(8) Remove the nut (7) and the washer (8).
(9) Remove the rheostat (9).
Subtask 33-12-17-020-051-A ** ON A/C NOT FOR ALL (1) Loosen the two fasteners (2).
(2) Carefully pull the panel 112VU (1).
(3) Remove the two screws (11) and disconnect the electrical connector (10).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (6) located on the knob (5), do not remove them.
(6) Remove the knob (5).
(7) Remove the two screws (4) and the placard (3).
(8) Remove the nut (7) and the washer (8).
(9) Remove the rheostat (9).
B. Removal of the Main Panel Flood Light Rheostat (35LE)
(1) Loosen the two fasteners (13).
(2) Carefully pull the panel 111VU (12).
(3) Remove the two screws (22) and disconnect the electrical connector (21).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (17) located on the knob (16), do not remove them.
(6) Remove the knob (16).
(7) Remove the two screws (15) and the placard (14).
(8) Remove the nut (18) and the washer (19).
(9) Remove the rheostat (20).
(1) Loosen the two fasteners (13).
(2) Carefully pull the panel 111VU (12).
(3) Remove the two screws (22) and disconnect the electrical connector (21).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (17) located on the knob (16), do not remove them.
(6) Remove the knob (16).
(7) Remove the two screws (15) and the placard (14).
(8) Remove the nut (18) and the washer (19).
(9) Remove the rheostat (20).
Main Panel and Pedestal Flood Light Rheostats