W DOC AIRBUS | AMM A320F

Installation of the Center Pedestal Light


TASK 33-12-14-400-002-A
Installation of the Center Pedestal Light


CAUTION: DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
ZONE: 210
FIN: 27LE
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
BULB
AIPC 33-12-14-01-020
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 33-12-00-710-001-A
Operational Test of the General Illumination
F Center Pedestal Light ** ON A/C NOT FOR ALL
F Center Pedestal Light ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 33-12-14-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
Subtask 33-12-14-941-050-A
B. Preparation for the Installation
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
4. Procedure
Subtask 33-12-14-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Bulb in the Center Pedestal Light
   (1) Install the AIPC 33-12-14-01-020 BULB (2)
   (2) Install the lens (1) on the body of the light (3).
Subtask 33-12-14-420-053-A ** ON A/C NOT FOR ALL
B. Installation of the Center Pedestal Light
   (1) Install the light (6) on the panel (7).
   (2) Install the circlips (4) on the light (6).
   (3) Connect the female electrical connectors (9) to the male electrical connectors (8).
   (4) Tighten the quick-disconnect fasteners (5) on the panel (7).
Subtask 33-12-14-420-053-B ** ON A/C NOT FOR ALL
B. Installation of the Center Pedestal Light
   (1) If the new center of pedestal light (3) already has the circlips (1), make sure you that you remove it before you install the center pedestal light (3).
   (2) Install the center pedestal light (3) on the overhead control and indicating panel 48VU (5).
   (3) Install the circlips (1) on the center pedestal light (3).
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (4) Connect the female electrical connectors (2) to the male electrical connectors (4).
   (5) Tighten the four quick-disconnect fasteners (6) on the overhead control and indicating panel 48VU (5).
Subtask 33-12-14-865-055-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
Subtask 33-12-14-710-051-A
5. Close-up
Subtask 33-12-14-942-051-A
A. Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 00:52:36 UTC