Replacement of the Lamp of the Center Instrument-Panel-Light
TASK 33-12-13-960-802-A
Replacement of the Lamp of the Center Instrument-Panel-Light
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 33-12-13-865-062-A ** ON A/C NOT FOR ALL
Subtask 33-12-13-020-055-A ** ON A/C NOT FOR ALL
Subtask 33-12-13-942-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:52:34 UTC
Replacement of the Lamp of the Center Instrument-Panel-Light
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
ZONE: 210
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | LAMP | AIPC 33-12-13-03-020 |
| 2 | LAMP | AIPC 33-12-13-03-040 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 33-12-00-710-001-A | Operational Test of the General Illumination |
Subtask 33-12-13-865-062-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CKPT/DOME | 1LE | H08 |
| 122VU | LIGHTING/FLOOD/CTR INST/PNL | 2LE | Z04 |
Subtask 33-12-13-020-055-A ** ON A/C NOT FOR ALL
A. Removal of the Lamp of the Center Instrument-Panel-Light
(1) Hold the blanking plate of the light (1) and loosen the three fasteners (3).
Subtask 33-12-13-420-055-A ** ON A/C NOT FOR ALL (1) Hold the blanking plate of the light (1) and loosen the three fasteners (3).
NOTE: Let the blanking plate of the light (1) open in the down position.
(2) Remove the defective lamp (2). B. Installation of the Lamp of the Center Instrument-Panel-Light
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install a new AIPC 33-12-13-03-020 LAMP (2) or AIPC 33-12-13-03-040 LAMP (2).
(4) Close the blanking plate of the light (1) in the up position.
(5) Tighten the three fasteners (3).
Subtask 33-12-13-865-063-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install a new AIPC 33-12-13-03-020 LAMP (2) or AIPC 33-12-13-03-040 LAMP (2).
(4) Close the blanking plate of the light (1) in the up position.
(5) Tighten the three fasteners (3).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-12-13-710-054-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/EMER LT/CKPT/DOME | 1LE | H08 |
| 122VU | LIGHTING/FLOOD/CTR INST/PNL | 2LE | Z04 |
Subtask 33-12-13-942-057-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
Main Instrument-Panel Center-Light