Replacement of the Lamp of the Center Instrument-Panel-Light


TASK 33-12-13-960-802-A
Replacement of the Lamp of the Center Instrument-Panel-Light


CAUTION: DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
LAMP
AIPC 33-12-13-03-020
2
LAMP
AIPC 33-12-13-03-040
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 33-12-00-710-001-A
Operational Test of the General Illumination
3. Job Set-up
Subtask 33-12-13-865-062-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CKPT/DOME1LEH08
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
4. Procedure
Subtask 33-12-13-020-055-A ** ON A/C NOT FOR ALL
A. Removal of the Lamp of the Center Instrument-Panel-Light
   (1) Hold the blanking plate of the light (1) and loosen the three fasteners (3).
NOTE: Let the blanking plate of the light (1) open in the down position.
   (2) Remove the defective lamp (2).
Subtask 33-12-13-420-055-A ** ON A/C NOT FOR ALL
B. Installation of the Lamp of the Center Instrument-Panel-Light
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Install a new AIPC 33-12-13-03-020 LAMP (2) or AIPC 33-12-13-03-040 LAMP (2).
   (4) Close the blanking plate of the light (1) in the up position.
   (5) Tighten the three fasteners (3).
Subtask 33-12-13-865-063-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CKPT/DOME1LEH08
122VULIGHTING/FLOOD/CTR INST/PNL2LEZ04
Subtask 33-12-13-710-054-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 33-12-13-942-057-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 00:52:34 UTC