W DOC AIRBUS | AMM A320F

Installation of the Map Table Light


TASK 33-12-12-400-804-A
Installation of the Map Table Light


CAUTION: DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
ZONE: 211
ZONE: 212
FIN: 41LE ** ON A/C NOT FOR ALL
FIN: 42LE ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 33-12-00-710-001-A
Operational Test of the General Illumination
3. Job Set-up
Subtask 33-12-12-865-066-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 41LE (LIGHTMAP TABLE, CAPT)
122VULIGHTING/FLOOD/CAPT/SIDE5LEZ05
FOR FIN: 42LE (LIGHTMAP TABLE, F/O)
122VULIGHTING/FLOOD/F/O/SIDE4LEZ06
4. Procedure
Subtask 33-12-12-160-052-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-12-12-420-062-A ** ON A/C NOT FOR ALL
B. Installation of the Map-Table Light
   (1) Pass the two electrical connectors of the map-table light (2) through the hole of the structure (1).
   (2) Put the support of the map-table light (11) on the structure (1).
   (3) Install and tighten the two screws (7) and (8).
   (4) Install the cover (9) with the screw (10).
   (5) Connect the two electrical connectors of the map-table light (2) to the two splices of the map-table light control-box (3).
NOTE: Make sure that you connect the wires of the same color.
   (6) Install the map-table light control-box (4) in its housing of the structure (1).
   (7) Install and tighten the four screws (6) and washers (5).
Subtask 33-12-12-865-067-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 41LE (LIGHTMAP TABLE, CAPT)
122VULIGHTING/FLOOD/CAPT/SIDE5LEZ05
FOR FIN: 42LE (LIGHTMAP TABLE, F/O)
122VULIGHTING/FLOOD/F/O/SIDE4LEZ06
Subtask 33-12-12-710-055-A ** ON A/C NOT FOR ALL
D. Do the operational test (Ref. AMM TASK 33-12-00-710-001).
5. Close-up
Subtask 33-12-12-942-055-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 00:52:27 UTC