Installation of the Map Table Light
TASK 33-12-12-400-804-A
Installation of the Map Table Light
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 33-12-12-865-066-A ** ON A/C NOT FOR ALL
Subtask 33-12-12-160-052-A ** ON A/C NOT FOR ALL
Subtask 33-12-12-942-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:52:27 UTC
Installation of the Map Table Light
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 33-12-00-710-001-A | Operational Test of the General Illumination |
Subtask 33-12-12-865-066-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 41LE (LIGHTMAP TABLE, CAPT) | |||
| 122VU | LIGHTING/FLOOD/CAPT/SIDE | 5LE | Z05 |
| FOR FIN: 42LE (LIGHTMAP TABLE, F/O) | |||
| 122VU | LIGHTING/FLOOD/F/O/SIDE | 4LE | Z06 |
Subtask 33-12-12-160-052-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-12-12-420-062-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Map-Table Light
(1) Pass the two electrical connectors of the map-table light (2) through the hole of the structure (1).
(2) Put the support of the map-table light (11) on the structure (1).
(3) Install and tighten the two screws (7) and (8).
(4) Install the cover (9) with the screw (10).
(5) Connect the two electrical connectors of the map-table light (2) to the two splices of the map-table light control-box (3).
(7) Install and tighten the four screws (6) and washers (5).
Subtask 33-12-12-865-067-A ** ON A/C NOT FOR ALL (1) Pass the two electrical connectors of the map-table light (2) through the hole of the structure (1).
(2) Put the support of the map-table light (11) on the structure (1).
(3) Install and tighten the two screws (7) and (8).
(4) Install the cover (9) with the screw (10).
(5) Connect the two electrical connectors of the map-table light (2) to the two splices of the map-table light control-box (3).
NOTE: Make sure that you connect the wires of the same color.
(6) Install the map-table light control-box (4) in its housing of the structure (1). (7) Install and tighten the four screws (6) and washers (5).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 33-12-12-710-055-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 41LE (LIGHTMAP TABLE, CAPT) | |||
| 122VU | LIGHTING/FLOOD/CAPT/SIDE | 5LE | Z05 |
| FOR FIN: 42LE (LIGHTMAP TABLE, F/O) | |||
| 122VU | LIGHTING/FLOOD/F/O/SIDE | 4LE | Z06 |
Subtask 33-12-12-942-055-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.