Removal of the Supplementary Reading Light and the Single Control Box
TASK 33-12-12-000-803-A
Removal of the Supplementary Reading Light and the Single Control Box
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-12-12-865-062-A ** ON A/C NOT FOR ALL
Subtask 33-12-12-020-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:52:25 UTC
Removal of the Supplementary Reading Light and the Single Control Box
CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS.
THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP.
IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT-FREE CLOTH.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 33-12-12-865-062-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/FLOOD/CTR INST/PNL | 2LE | Z04 |
Subtask 33-12-12-020-059-A ** ON A/C NOT FOR ALL
A. Removal of the Supplementary Reading Light (29LE)
(1) Loosen the four quick-disconnect fasteners (2) from the reading-light panel 54VU (3).
(3) Remove the circlips (1) from the supplementary reading light (6).
(4) Remove the supplementary reading light (6).
Subtask 33-12-12-020-060-A ** ON A/C NOT FOR ALL (1) Loosen the four quick-disconnect fasteners (2) from the reading-light panel 54VU (3).
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(2) Disconnect the female electrical connectors (4) from the male electrical connectors (5) of the supplementary reading light (6). (3) Remove the circlips (1) from the supplementary reading light (6).
(4) Remove the supplementary reading light (6).
B. Removal of the Reading Light Single-Control-Box (51LE)
(1) Loosen the four quick-disconnect fasteners (2) from the reading-light panel 54VU (3).
(2) Carefully pull the reading-light panel 54VU (3).
(3) Remove the two screws (15) and disconnect the electrical connector (14).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (9) installed on the knob (8) but do not remove them.
(6) Remove the knob (8).
(7) Remove the four screws (10) and the integrally lighted plate (7).
(8) Remove the nut (11) and washer (12).
(9) Remove the single control box (13).
(1) Loosen the four quick-disconnect fasteners (2) from the reading-light panel 54VU (3).
(2) Carefully pull the reading-light panel 54VU (3).
(3) Remove the two screws (15) and disconnect the electrical connector (14).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the two screws (9) installed on the knob (8) but do not remove them.
(6) Remove the knob (8).
(7) Remove the four screws (10) and the integrally lighted plate (7).
(8) Remove the nut (11) and washer (12).
(9) Remove the single control box (13).
Illustration of the Reading Light