W DOC AIRBUS | AMM A320F

Inspection of the MLG Proximity Sensor and Target Clearances


TASK 32-31-73-200-001-A
Inspection of the MLG Proximity Sensor and Target Clearances


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 734
ZONE: 744
1. Reason for the Job
NOTE: This procedure is for proximity sensors 14GA, 15GA, 16GA, 17GA, 20GA, 21GA, 22GA, 23GA, 32GA, 33GA, 34GA and 35GA only.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
734
MAIN DOOR
744
MAIN DOOR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 07-11-00-581-001-A
Lifting for Aircraft Maintenance Operations
TASK 07-11-00-586-002-A
Lowering of the Aircraft for Maintenance Operations
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 32-00-00-481-001-A
Installation of the Safety Devices on the Landing Gears
TASK 32-00-00-860-001-A
Flight Configuration Precautions with Electrical Power
TASK 32-00-00-860-001-A-01
Flight Configuration Precautions without Electrical Power
TASK 32-00-00-860-002-A
Ground Configuration after Flight Configuration with Electrical Power
TASK 32-00-00-860-002-A-01
Ground Configuration after Flight Configuration without Electrical Power
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 32-31-73-820-001-A
Adjustment of the MLG Downlock Proximity Sensors
TASK 32-31-73-820-002-A
Adjustment of the MLG Extension Proximity Sensors
TASK 32-31-73-820-003-A
Adjustment of the MLG Door Open Proximity Sensors
TASK 32-69-00-740-001-A
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Job Set-up
Subtask 32-31-73-941-054-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) Make sure that the ground safety locks are installed on the landing gear (Ref. AMM TASK 32-00-00-481-001).
   (3) On the panel 400VU:
  • make sure that the landing-gear control-lever 6GA is in the DOWN position
  • put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear and the MLG doors.
Subtask 32-31-73-582-053-A
B. Aircraft Maintenance Configuration
   (1) If you are to do a check of the MLG proximity sensors 20GA, 21GA, 22GA and 23GA, lift the aircraft on jacks (Ref. AMM TASK 07-11-00-581-001).
Subtask 32-31-73-010-053-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position below the applicable zone 734(744).
   (2) Open the applicable MLG door (Ref. AMM TASK 32-12-00-010-001).
Subtask 32-31-73-869-056-A
D. Flight Configuration Precautions
   (1) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
   (2) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
Subtask 32-31-73-865-065-A
E. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
121VULGCIU/BAT SPLY/SYS158GAR32
** ON A/C ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
121VULGCIU/BAT SPLY/SYS158GAR31
4. Procedure
Subtask 32-31-73-220-077-F ** ON A/C NOT FOR ALL
A. Inspection of the MLG Proximity Sensor and Target Clearances
NOTE: For the dimensions 'new' and 'in service', you must refer to the list that follows:
  • when the two interface components are new, you must refer to the new dimensions
  • when one interface component is new and the other component is in service, you must refer to the in service dimensions
  • when the two interface components are in service, you must refer to the in service dimensions.
    'New' refers to a component not used since it was made.
    'In service' refers to a component that has been overhauled or used since it was made.
   (1) For the MLG downlock proximity sensors 14GA (15GA) (System 1):
     (a) For a new MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
       2 Measure the dimension X:
  • make sure it is between 0.7 mm (0.0276 in.) and 0.9 mm (0.0354 in.).
     (b) For an in service MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 0.6 mm (0.0236 in.) and 2.4 mm (0.0945 in.).
       2 Measure the dimension X:
  • make sure it is between 0.35 mm (0.0138 in.) and 1.25 mm (0.0492 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 14GA (15GA) (Ref. AMM TASK 32-31-73-820-001).
   (2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
     (a) For a new MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
       2 Measure the dimension X:
  • make sure it is between 2.4 mm (0.0945 in.) and 2.6 mm (0.1024 in.).
     (b) For an in service lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0768 in.).
       2 Measure the dimension X:
  • make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 16GA (17GA) (Ref. AMM TASK 32-31-73-820-001).
   (3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
F MLG Extension Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
     (b) Measure the dimension X:
  • make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 20GA (21GA) (Ref. AMM TASK 32-31-73-820-002).
   (4) For the MLG extension proximity sensors 23GA (22GA) (System 2):
F MLG Extension Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
     (b) Measure the dimension X:
  • make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 22GA (23GA) (Ref. AMM TASK 32-31-73-820-002).
   (5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
F MLG Door Open Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension X:
  • make sure it is between -2.5 mm (-0.0984 in.) and 2.5 mm (0.0984 in.)
     (b) Measure the dimension Z:
  • make sure it is between 1.5 mm (0.0591 in.) and 2.5 mm (0.0984 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG door open proximity sensors 32GA (33GA), 34GA (35GA) (Ref. AMM TASK 32-31-73-820-003).
Subtask 32-31-73-220-077-G ** ON A/C NOT FOR ALL
A. Inspection of the MLG Proximity Sensor and Target Clearances
NOTE: For the dimensions 'new' and 'in service', you must refer to the list that follows:
  • when the two interface components are new, you must refer to the new dimensions
  • when one interface component is new and the other component is in service, you must refer to the in service dimensions
  • when the two interface components are in service, you must refer to the in service dimensions.
    'New' refers to a component not used since it was made.
    'In service' refers to a component that has been overhauled or used since it was made.
   (1) For the MLG downlock proximity sensors 14GA (15GA) (System 1):
     (a) For a new MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
       2 Measure the dimension X:
  • make sure it is between 0.7 mm (0.0276 in.) and 0.9 mm (0.0354 in.).
     (b) For an in service MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 0.6 mm (0.0236 in.) and 2.4 mm (0.0945 in.).
       2 Measure the dimension X:
  • make sure it is between 0.35 mm (0.0138 in.) and 1.25 mm (0.0492 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 14GA (15GA) (Ref. AMM TASK 32-31-73-820-001).
   (2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
     (a) For a new MLG lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
       2 Measure the dimension X:
  • make sure it is between 2.4 mm (0.0945 in.) and 2.6 mm (0.1024 in.).
     (b) For an in service lockstay or sidestay:
       1 Measure the dimension Z:
  • make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0768 in.).
       2 Measure the dimension X:
  • make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 16GA (17GA) (Ref. AMM TASK 32-31-73-820-001).
   (3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
F MLG Extension Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
     (b) Measure the dimension X:
  • make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 20GA (21GA) (Ref. AMM TASK 32-31-73-820-002).
   (4) For the MLG extension proximity sensors 22GA (23GA) (System 2):
F MLG Extension Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension Z:
  • make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
     (b) Measure the dimension X:
  • make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 22GA (23GA) (Ref. AMM TASK 32-31-73-820-002).
   (5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
F MLG Door Open Proximity Sensor ** ON A/C NOT FOR ALL
     (a) Measure the dimension X:
  • make sure it is between -2.5 mm (-0.0984 in.) and 2.5 mm (0.0984 in.).
     (b) Measure the dimension Z:
  • make sure it is between 1.5 mm (0.0591 in.) and 2.5 mm (0.0984 in.).
     (c) If the dimensions are incorrect, do the adjustment of the MLG door open proximity sensors 32GA (33GA), 34GA (35GA) (Ref. AMM TASK 32-31-73-820-003).
Subtask 32-31-73-586-052-A
B. Aircraft Maintenance Configuration
   (1) If you did a check of the proximity sensors 20GA, 21GA, 22GA and 23GA, lower the aircraft off jacks (Ref. AMM TASK 07-11-00-586-002).
Subtask 32-31-73-865-066-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
121VULGCIU/BAT SPLY/SYS158GAR32
** ON A/C ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
121VULGCIU/BAT SPLY/SYS158GAR31
Subtask 32-31-73-869-057-A
D. Flight Configuration Precautions
   (1) If you did the flight configuration precautions, put the aircraft back to the ground configuration (Ref. AMM TASK 32-00-00-860-002).
Subtask 32-31-73-410-054-A
E. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Close the applicable MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 32-31-73-740-055-A
F. Test
   (1) Do a BITE test of the landing gear (Ref. AMM TASK 32-69-00-740-001).
5. Close-up
Subtask 32-31-73-942-055-A
A. Removal of Equipment
   (1) Remove the SAFETY BARRIER(S).
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.