Inspection of the MLG Proximity Sensor and Target Clearances
TASK 32-31-73-200-001-A
Inspection of the MLG Proximity Sensor and Target Clearances
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 32-31-73-941-054-A
Subtask 32-31-73-220-077-F ** ON A/C NOT FOR ALL
Subtask 32-31-73-942-055-A
[Rev.10 from 2021]
2026.04.01 00:46:07 UTC
Inspection of the MLG Proximity Sensor and Target Clearances
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
NOTE: This procedure is for proximity sensors 14GA, 15GA, 16GA, 17GA, 20GA, 21GA, 22GA, 23GA, 32GA, 33GA, 34GA and 35GA only.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 734 | MAIN DOOR |
| 744 | MAIN DOOR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 07-11-00-581-001-A | Lifting for Aircraft Maintenance Operations |
| TASK 07-11-00-586-002-A | Lowering of the Aircraft for Maintenance Operations |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 32-00-00-481-001-A | Installation of the Safety Devices on the Landing Gears |
| TASK 32-00-00-860-001-A | Flight Configuration Precautions with Electrical Power |
| TASK 32-00-00-860-001-A-01 | Flight Configuration Precautions without Electrical Power |
| TASK 32-00-00-860-002-A | Ground Configuration after Flight Configuration with Electrical Power |
| TASK 32-00-00-860-002-A-01 | Ground Configuration after Flight Configuration without Electrical Power |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 32-31-73-820-001-A | Adjustment of the MLG Downlock Proximity Sensors |
| TASK 32-31-73-820-002-A | Adjustment of the MLG Extension Proximity Sensors |
| TASK 32-31-73-820-003-A | Adjustment of the MLG Door Open Proximity Sensors |
| TASK 32-69-00-740-001-A | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
Subtask 32-31-73-941-054-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Make sure that the ground safety locks are installed on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(3) On the panel 400VU:
Subtask 32-31-73-582-053-A (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Make sure that the ground safety locks are installed on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(3) On the panel 400VU:
- make sure that the landing-gear control-lever 6GA is in the DOWN position
- put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear and the MLG doors.
B. Aircraft Maintenance Configuration
(1) If you are to do a check of the MLG proximity sensors 20GA, 21GA, 22GA and 23GA, lift the aircraft on jacks (Ref. AMM TASK 07-11-00-581-001).
Subtask 32-31-73-010-053-A (1) If you are to do a check of the MLG proximity sensors 20GA, 21GA, 22GA and 23GA, lift the aircraft on jacks (Ref. AMM TASK 07-11-00-581-001).
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the applicable zone 734(744).
(2) Open the applicable MLG door (Ref. AMM TASK 32-12-00-010-001).
Subtask 32-31-73-869-056-A (1) Put the ACCESS PLATFORM 2M (6 FT) in position below the applicable zone 734(744).
(2) Open the applicable MLG door (Ref. AMM TASK 32-12-00-010-001).
D. Flight Configuration Precautions
(1) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(2) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
Subtask 32-31-73-865-065-A (1) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(2) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
E. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R33 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R32 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R32 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R31 |
Subtask 32-31-73-220-077-F ** ON A/C NOT FOR ALL
A. Inspection of the MLG Proximity Sensor and Target Clearances
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
1 Measure the dimension Z:
(2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
1 Measure the dimension Z:
(3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
(a) Measure the dimension Z:
(4) For the MLG extension proximity sensors 23GA (22GA) (System 2):
(a) Measure the dimension Z:
(5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
(a) Measure the dimension X:
Subtask 32-31-73-220-077-G ** ON A/C NOT FOR ALL NOTE: For the dimensions 'new' and 'in service', you must refer to the list that follows:
(1) For the MLG downlock proximity sensors 14GA (15GA) (System 1): - when the two interface components are new, you must refer to the new dimensions
- when one interface component is new and the other component is in service, you must refer to the in service dimensions
- when the two interface components are in service, you must refer to the in service dimensions.
'New' refers to a component not used since it was made.
'In service' refers to a component that has been overhauled or used since it was made.
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 0.7 mm (0.0276 in.) and 0.9 mm (0.0354 in.).
1 Measure the dimension Z:
- make sure it is between 0.6 mm (0.0236 in.) and 2.4 mm (0.0945 in.).
- make sure it is between 0.35 mm (0.0138 in.) and 1.25 mm (0.0492 in.).
(2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 2.4 mm (0.0945 in.) and 2.6 mm (0.1024 in.).
1 Measure the dimension Z:
- make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0768 in.).
- make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
(3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
(a) Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
(4) For the MLG extension proximity sensors 23GA (22GA) (System 2):
(a) Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
(5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
(a) Measure the dimension X:
- make sure it is between -2.5 mm (-0.0984 in.) and 2.5 mm (0.0984 in.)
- make sure it is between 1.5 mm (0.0591 in.) and 2.5 mm (0.0984 in.).
A. Inspection of the MLG Proximity Sensor and Target Clearances
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
1 Measure the dimension Z:
(2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
1 Measure the dimension Z:
(3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
(a) Measure the dimension Z:
(4) For the MLG extension proximity sensors 22GA (23GA) (System 2):
(a) Measure the dimension Z:
(5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
(a) Measure the dimension X:
Subtask 32-31-73-586-052-A NOTE: For the dimensions 'new' and 'in service', you must refer to the list that follows:
(1) For the MLG downlock proximity sensors 14GA (15GA) (System 1): - when the two interface components are new, you must refer to the new dimensions
- when one interface component is new and the other component is in service, you must refer to the in service dimensions
- when the two interface components are in service, you must refer to the in service dimensions.
'New' refers to a component not used since it was made.
'In service' refers to a component that has been overhauled or used since it was made.
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 0.7 mm (0.0276 in.) and 0.9 mm (0.0354 in.).
1 Measure the dimension Z:
- make sure it is between 0.6 mm (0.0236 in.) and 2.4 mm (0.0945 in.).
- make sure it is between 0.35 mm (0.0138 in.) and 1.25 mm (0.0492 in.).
(2) For the MLG downlock proximity sensors 16GA (17GA) (System 2):
(a) For a new MLG lockstay or sidestay:
1 Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 2.4 mm (0.0945 in.) and 2.6 mm (0.1024 in.).
1 Measure the dimension Z:
- make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0768 in.).
- make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
(3) For the MLG extension proximity sensors 20GA (21GA) (System 1):
(a) Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
(4) For the MLG extension proximity sensors 22GA (23GA) (System 2):
(a) Measure the dimension Z:
- make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0630 in.).
- make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).
(5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA):
(a) Measure the dimension X:
- make sure it is between -2.5 mm (-0.0984 in.) and 2.5 mm (0.0984 in.).
- make sure it is between 1.5 mm (0.0591 in.) and 2.5 mm (0.0984 in.).
B. Aircraft Maintenance Configuration
(1) If you did a check of the proximity sensors 20GA, 21GA, 22GA and 23GA, lower the aircraft off jacks (Ref. AMM TASK 07-11-00-586-002).
Subtask 32-31-73-865-066-A (1) If you did a check of the proximity sensors 20GA, 21GA, 22GA and 23GA, lower the aircraft off jacks (Ref. AMM TASK 07-11-00-586-002).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 32-31-73-869-057-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R33 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R32 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R32 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R31 |
D. Flight Configuration Precautions
(1) If you did the flight configuration precautions, put the aircraft back to the ground configuration (Ref. AMM TASK 32-00-00-860-002).
Subtask 32-31-73-410-054-A (1) If you did the flight configuration precautions, put the aircraft back to the ground configuration (Ref. AMM TASK 32-00-00-860-002).
E. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the applicable MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 32-31-73-740-055-A 5. Close-up(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the applicable MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 32-31-73-942-055-A
A. Removal of Equipment
(1) Remove the SAFETY BARRIER(S).
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the SAFETY BARRIER(S).
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
MLG Downlock Proximity Sensor (System 1)