W DOC AIRBUS | AMM A320F

Removal of the NLG Door Ground Opening Bypass Valve


TASK 32-31-15-000-001-A
Removal of the NLG Door Ground Opening Bypass Valve


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
ZONE: 124
FIN: 2533GM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
124
NOSE GEAR WELL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 32-22-00-010-001-A
Nose Gear Doors - Ground Doors Opening
3. Job Set-up
Subtask 32-31-15-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the Green hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001)
   (2) Depressurize the reservoir of the Green hydraulic system
(Ref. AMM TASK 29-14-00-614-001)
Subtask 32-31-15-010-050-A
B. Get Access
   (1) Open the doors of the nose landing gear (Ref. AMM TASK 32-22-00-010-001).
   (2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in zone 123.
Subtask 32-31-15-941-050-A
C. Safety Precautions
   (1) In the cockpit, on the panel 400VU, put WARNING NOTICE(S) in position to tell persons not to operate the landing gear control lever.
   (2) Put the WARNING NOTICE(S) in position to tell persons not pressurize the Green hydraulic system:
  • on the panel 40VU in the cockpit,
  • on the ground service panel of the Green hydraulic system, access door (197CB).
   (3) Put the SAFETY BARRIER(S) in position.
   (4) Put a CONTAINER 5 L (1.32 USGAL) in position below the NLG door ground opening bypass valve (2533GM).
4. Procedure
Subtask 32-31-15-020-051-A
A. Removal of the NLG Door Ground Opening Bypass Valve
WARNING: MAKE SURE THAT THE NLG DOWNLOCK SAFETY PIN AND THE TWO DOOR SAFETY PINS ARE INSTALLED.
   (1) Disconnect the hydraulic lines (1), (10) and (11). Put the PLUG - BLANKING on the disconnected line ends.
   (2) Remove the reducers (2) and (12). Remove the restrictor (9). Remove and discard the packings (3), (8) and (13).
   (3) Remove the cotter pin (27) and discard it. Remove the nut (26) and the washer (25).
   (4) Remove the bolt (22) and disconnect the rod (17).
   (5) Remove the cotter pin (18) and discard it. Remove the nut (19) and the washer (20).
   (6) Remove the screw (24) and the lever (23).
   (7) Remove the cotter pins (5) and discard them. Remove the nuts (4) and the washers (6).
   (8) Remove the bolts (14).
   (9) Remove the selector valve (7).
[Rev.10 from 2021] 2026.04.01 00:44:27 UTC