W DOC AIRBUS | AMM A320F

Removal of the Landing Gear Normal Control lever


TASK 32-31-11-000-001-A
Removal of the Landing Gear Normal Control lever


WARNING: MAKE SURE THAT THE GROUND SAFETY LOCKS ARE CORRECTLY INSTALLED ON THE MLG AND NLG. MOVEMENTS OF THE LANDING GEARS CAN CAUSE INJURY TO PERSONS AND CAUSE DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
ZONE: 211
FIN: 6GA
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 32-00-00-481-001-A
Installation of the Safety Devices on the Landing Gears
TASK 32-00-00-860-001-A
Flight Configuration Precautions with Electrical Power
TASK 32-00-00-860-001-A-01
Flight Configuration Precautions without Electrical Power
3. Job Set-up
Subtask 32-31-11-860-050-A
A. Aircraft Maintenance Configuration
   (1) Obey the applicable safety precautions before you open the LGCIU circuit breakers (Ref. AMM TASK 32-00-00-860-001).
   (2) Make sure that the safety devices are installed on the MLG and NLG (Ref. AMM TASK 32-00-00-481-001).
Subtask 32-31-11-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
121VULGCIU/BAT SPLY/SYS158GAR32
** ON A/C ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
121VULGCIU/BAT SPLY/SYS158GAR31
Subtask 32-31-11-010-050-A
C. Remove the thermoformed cover from the center instrument panel.
4. Procedure
Subtask 32-31-11-020-050-A
A. Removal of the L/G Control Lever
   (1) Loosen the two screws (3). Do not remove them.
   (2) Pull the L/G control lever (4) from its housing.
   (3) Disconnect the electrical connectors (1) and (2) from the L/G control lever (4).
   (4) Remove the L/G control lever (4).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.01 00:44:17 UTC