W DOC AIRBUS | AMM A320F

Removal of the Display Unit (DU)


TASK 31-63-22-000-001-A
Removal of the Display Unit (DU)


ZONE: 210
FIN: 2WT1
FIN: 2WT2
FIN: 3WT1
FIN: 3WT2
FIN: 4WT1
FIN: 4WT2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 31-63-22-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 2WT1 (PFDCAPT)
49VUEIS/PFD CAPT/SPLY11WT1E03
** ON A/C ALL
49VUEIS/PFD CAPT/SWTG22WT1E04
** ON A/C NOT FOR ALL
49VUEIS/PFD/CAPT/SPLY11WT1E03
** ON A/C ALL
FOR FIN: 2WT2 (PFDF/O)
121VUEIS/PFD/F/O/SWTG22WT2R05
121VUEIS/PFD/F/O11WT2R03
FOR FIN: 3WT1 (NDCAPT)
49VUEIS/ND CAPT/SWTG23WT1E02
49VUEIS/ND CAPT/SPLY12WT1E01
FOR FIN: 3WT2 (NDF/O)
121VUEIS/ND/F/O/SWTG23WT2R06
121VUEIS/ND/F/O12WT2R04
FOR FIN: 4WT1 (DUECAM, UPPER)
49VUEIS/ECAM DU/UPPER/SWTG24WT1E06
49VUEIS/ECAM DU/UPPER/SPLY13WT1E05
FOR FIN: 4WT2 (DUECAM, LOWER)
121VUEIS/ECAM DU/LOWER/SPLY13WT2R11
121VUEIS/ECAM DU/LOWER/SWTG24WT2R10
4. Procedure
Subtask 31-63-22-020-050-A
A. Removal of the Display Unit (DU)
   (1) FOR [2WT1] (PFD-CAPT), [3WT1] (ND-CAPT)
Remove the thermoformed cover from the CAPT main instrument panel.
     (a) FOR [2WT2] (PFD-F/O), [3WT2] (ND-F/O)
Remove the thermoformed cover from the F/O main instrument panel.
     (b) FOR [4WT1] (DU-ECAM, UPPER), [4WT2] (DU-ECAM, LOWER)
Remove the thermoformed cover from the center instrument panel.
   (2) Push in the two locking catches (4).
   (3) If necessary, push up the handle (3) to decrease the load applied to the locking catches (4): the handle (3) falls to the level of the studs.
   (4) Slowly and continuously lower the handle (3) to the bottom section of the screen : at the same time, the DU (2) moves out from the panel by approximately 3 cm.
   (5) Pull the handle (3) found at the removal point and disengage the DU (2).
   (6) Remove the DU (2).
   (7) Put CAP - BLANKING on the electrical connectors (1).
   (8) Put the DU (2) in the replacement unit container.
[Rev.10 from 2021] 2026.04.01 00:38:26 UTC