W DOC AIRBUS | AMM A320F

Installation of the Cursor Control Device (CCD)


TASK 31-61-14-400-801-A
Installation of the Cursor Control Device (CCD)


ZONE: 211
ZONE: 212
FIN: 35WT ** ON A/C NOT FOR ALL
FIN: 36WT ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 31-61-00-710-801-A
Operational test of the Cursor Control Device (CCD)
TASK 34-38-00-740-801-A
BITE Test of the Onboard Aircraft Navigation System (OANS) (System Test)
3. Job Set-up
Subtask 31-61-14-865-051-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 35WT (CCD CAPTAIN)
121VUOANS CCD CAPT37WTL11
FOR FIN: 36WT (CCD FIRST OFFICER)
121VUOANS CCD F/O38WTL09
4. Procedure
Subtask 31-61-14-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the CCD
   (1) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (2) Connect the electrical connector (3) to the CCD (4).
   (3) Make sure that all the electrical connections are clean and in the correct condition.
   (4) Put the CCD (4) in position on the cover (2).
   (5) Install and tighten the three screws (1).
Subtask 31-61-14-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 35WT (CCD CAPTAIN)
121VUOANS CCD CAPT37WTL11
FOR FIN: 36WT (CCD FIRST OFFICER)
121VUOANS CCD F/O38WTL09
Subtask 31-61-14-740-050-A ** ON A/C NOT FOR ALL
C. BITE Test
   (1) Do a BITE test of the OANS (System Test) (Ref. AMM TASK 34-38-00-740-801).
Subtask 31-61-14-710-050-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do an operational test of the CCD (Ref. AMM TASK 31-61-00-710-801).
5. Close-up
Subtask 31-61-14-942-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 00:38:14 UTC