W DOC AIRBUS | AMM A320F

Removal of the SDAC


TASK 31-55-34-000-001-A
Removal of the SDAC


ZONE: 127
ZONE: 128
FIN: 1WV1
FIN: 1WV2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-32-00-860-008-A
Procedure to Get Access to the SYSTEM REPORT/TEST/INST Page
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
Subtask 31-55-34-810-050-A
A. Printing of Trouble Shooting Data (TSD)
NOTE: TSD are used for analysis and TSM (detailed troubleshooting).
   (1) If available, you can print the TSD as follows:
     (a) Get the SYSTEM REPORT/TEST/INST menu page (Ref. AMM TASK 31-32-00-860-008).
     (b) On this page, push the line key adjacent to the ECAM 1 or ECAM 2 page.
     (c) On the ECAM 1 or ECAM 2 page, push the line key adjacent to the LAST LEG REPORT page or PREVIOUS LEG REPORT page.
     (d) Do a print of the TSD with the maintenance message and add the printed TSD sheet to the removed computer.
Subtask 31-55-34-865-055-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 1WV1 (SDAC1)
49VUSDAC/1 AND 2/28VDC/ESS BUS12WVF05
49VUSDAC/1/SPLY3WVF04
49VUSDAC/1/26VAC SYNC/AC ESS BUS5WVF02
** ON A/C NOT FOR ALL
121VUEIS/SDAC/1/BUS1/26VAC SYNC AC9WVQ04
** ON A/C ALL
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
121VUEIS/SDAC/1/BUS2/26VAC SYNC AC7WVQ03
FOR FIN: 1WV2 (SDAC2)
49VUSDAC/1 AND 2/28VDC/ESS BUS12WVF05
49VUSDAC/2/26VAC SYNC/AC ESS BUS6WVF03
121VUEIS/SDAC/2/SPLY2WVQ06
121VUEIS/SDAC/2/BUS1/26VAC SYNC AC10WVQ05
121VUEIS/SDAC/2/BUS2/26VAC SYNC AC8WVQ02
Subtask 31-55-34-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
   (2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 31-55-34-020-050-A
A. Removal of the SDAC
   (1) Loosen the nuts (3) on the front of the rack (2).
   (2) Lower the nuts (3).
   (3) Pull the SDAC (5) on its rack (2) to disconnect the electrical connectors (1).
   (4) Remove the SDAC (5) from its rack (2).
   (5) Put CAP - BLANKING on the disconnected electrical connectors (1).
[Rev.10 from 2021] 2026.04.01 00:37:31 UTC