Removal of the Data Loading Selector Unit (DLSU)
TASK 31-38-23-000-801-A
Removal of the Data Loading Selector Unit (DLSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-38-23-865-050-A ** ON A/C NOT FOR ALL
Subtask 31-38-23-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:36:41 UTC
Removal of the Data Loading Selector Unit (DLSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 31-38-23-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | DATA/LOADER/SPLY | 3TD | J16 |
| 121VU | DLSU &/DLRB/SPLY | 5TD | J15 |
| 121VU | PDL/PWR/SPLY | 14TD | K19 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | PDL/PWR/SPLY | 14TD | J45 |
| 121VU | DATA/LOADER/SPLY | 3TD | J39 |
| 121VU | DLSU &/DLRB/SPLY | 5TD | J38 |
Subtask 31-38-23-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Data Loading Selector Unit (DLSU)
(1) Loosen the quarter-turn fasteners (2).
(2) Pull the DLSU (1) from its housing.
(3) Disconnect the electrical connectors (3).
(4) Remove the DLSU (1) from its housing.
(5) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
(1) Loosen the quarter-turn fasteners (2).
(2) Pull the DLSU (1) from its housing.
(3) Disconnect the electrical connectors (3).
(4) Remove the DLSU (1) from its housing.
(5) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
Data Loading Selector Unit (DLSU)