W DOC AIRBUS | AMM A320F

Removal of the Wireless Ground Link Digital AIDS Recorder (WGL-DAR)


TASK 31-36-52-000-002-A
Removal of the Wireless Ground Link Digital AIDS Recorder (WGL-DAR)


ZONE: 127
FIN: 2TV ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-36-00-000-803-A
Removal of the Removable SIM Module (RSM) and the SIM Module I/O Cards (SMIO) of the WGL-DAR
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
3. Job Set-up
Subtask 31-36-52-865-066-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/FDIMU5TVK15
Subtask 31-36-52-010-060-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in zone 128, at access door 824.
   (2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 31-36-52-020-059-C ** ON A/C NOT FOR ALL
A. Removal of the Wireless Ground Link Digital AIDS Recorder (WGL-DAR)
   (1) Remove the Removable SIM Module (RDS) or SIM cards (Ref. AMM TASK 31-36-00-000-803).
   (2) Loosen the nuts (3).
   (3) Lower the nuts (3).
   (4) Pull the WGL-DAR (1) on its rack (2) to disconnect the electrical connectors (5).
   (5) Remove the WGL-DAR (1) from its rack (2).
   (6) Put CAP - BLANKING on the disconnected electrical connectors (5).
[Rev.10 from 2021] 2026.04.01 00:36:10 UTC