Installation of the Data Management Unit (DMU)
TASK 31-36-34-400-001-A
Installation of the Data Management Unit (DMU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-34-860-050-A ** ON A/C NOT FOR ALL
Subtask 31-36-34-420-050-D ** ON A/C NOT FOR ALL
Subtask 31-36-34-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:36:08 UTC
Installation of the Data Management Unit (DMU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 31-36-00-710-001-A | Test of the DMU |
| TASK 31-36-00-710-004-A | AIDS Software Load Procedure |
| TASK 31-36-00-710-008-A | AIDS Software Load Procedure through the PCMCIA-Card (PCMCIA = Personal Computer Memory Card International Association) |
| TASK 31-36-00-740-004-A | Update of the APU Hours and Cycles in the DMU after APU, ECB or DMU Replacement |
| TASK 31-36-00-740-005-A | Update of the Engine Hours and Cycles in the DMU after Engine or DMU Replacement |
| TASK 31-36-00-740-009-A | DMU Programming Procedures |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-36-34-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open.
(3) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002)
(4) Energize the CFDS
Subtask 31-36-34-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open.
(3) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002)
(4) Energize the CFDS
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS/DMU | 4TV | K15 |
Subtask 31-36-34-420-050-D ** ON A/C NOT FOR ALL
A. Installation of the Data Management Unit (DMU)
(1) Clean the component interfaces and the adjacent area.
(2) Make an inspection of the component interface and/or the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2).
(4) Make sure that the electrical connectors (2) are clean and in the correct condition.
(5) Install the DMU (1) on its rack (3).
(6) Push the DMU (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
(8) Switch the operating/storage switch to the operating position.
Subtask 31-36-34-865-052-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Make an inspection of the component interface and/or the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2).
(4) Make sure that the electrical connectors (2) are clean and in the correct condition.
(5) Install the DMU (1) on its rack (3).
(6) Push the DMU (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
(8) Switch the operating/storage switch to the operating position.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-36-34-554-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS/DMU | 4TV | K15 |
C. Do the AIDS Software Load Procedure (Ref. AMM TASK 31-36-00-710-004) (Ref. AMM TASK 31-36-00-710-008)
Subtask 31-36-34-554-052-A ** ON A/C NOT FOR ALL D. Do the steps that follow:
(1) Do the updating of APU hours and cycles data (Ref. AMM TASK 31-36-00-740-004) and of Engine hours and cycles data (Ref. AMM TASK 31-36-00-740-005).
(2) Do the DMU programming procedures (Ref. AMM TASK 31-36-00-740-009).
Subtask 31-36-34-710-051-A ** ON A/C NOT FOR ALL 5. Close-up(1) Do the updating of APU hours and cycles data (Ref. AMM TASK 31-36-00-740-004) and of Engine hours and cycles data (Ref. AMM TASK 31-36-00-740-005).
(2) Do the DMU programming procedures (Ref. AMM TASK 31-36-00-740-009).
NOTE: If the Programmable Report Inhibit and Programmable Report Limits procedures were done before with the GSE, it is not necessary to do them again.
Subtask 31-36-34-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
Data Management Unit (DMU)