W DOC AIRBUS | AMM A320F

Replacement of the FDIMU Batteries


TASK 31-36-00-960-003-A
Replacement of the FDIMU Batteries


ZONE: 120
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-36-00-740-012-A
Test of the Flight Data Interface and Management Unit (FDIMU)
TASK 31-36-34-000-002-A
Removal of the FDIU/DMU (FDIMU)
TASK 31-36-34-400-002-A
Installation of the FDIU/DMU (FDIMU)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 31-36-00-010-068-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position, at access door 824.
   (2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-36-00-865-095-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAIDS & RCDR/FDIMU5TVK15
Subtask 31-36-00-000-054-A ** ON A/C NOT FOR ALL
C. Component Removal
   (1) Remove the FDIMU (Ref. AMM TASK 31-36-34-000-002).
4. Procedure
Subtask 31-36-00-960-051-A ** ON A/C NOT FOR ALL
A. Replacement of FDIMU Batteries
   (1) Removal of the FDIMU Batteries:

     (a) Loosen the captive screws (1) on the battery housing cover (2) on the rear panel of the unit.

     (b) Remove the battery housing cover (2).

     (c) Remove the batteries (3).

   (2) Installation of the FDIMU Batteries:

     (a) Install the new batteries (3) in the rear of the unit. Make sure the polarity (+/-) is correct.

     (b) Put the battery housing cover (2) in position on the rear of the unit.

     (c) Tighten the captive screws (1).

5. Close-up
Subtask 31-36-00-400-054-A ** ON A/C NOT FOR ALL
A. Component Installation
   (1) Install the FDIMU (Ref. AMM TASK 31-36-34-400-002).
Subtask 31-36-00-710-081-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the operational test of the FDIMU (Ref. AMM TASK 31-36-00-740-012).
Subtask 31-36-00-410-067-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 00:35:55 UTC