Replacement of the FDIMU Batteries
TASK 31-36-00-960-003-A
Replacement of the FDIMU Batteries
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-00-010-068-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-960-051-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-400-054-A ** ON A/C NOT FOR ALL Subtask 31-36-00-710-081-A ** ON A/C NOT FOR ALL Subtask 31-36-00-410-067-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:35:55 UTC
Replacement of the FDIMU Batteries
ZONE: 120
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 31-36-00-740-012-A | Test of the Flight Data Interface and Management Unit (FDIMU) |
| TASK 31-36-34-000-002-A | Removal of the FDIU/DMU (FDIMU) |
| TASK 31-36-34-400-002-A | Installation of the FDIU/DMU (FDIMU) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-36-00-010-068-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position, at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-36-00-865-095-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) in position, at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 31-36-00-000-054-A ** ON A/C NOT FOR ALL 4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
Subtask 31-36-00-960-051-A ** ON A/C NOT FOR ALL
A. Replacement of FDIMU Batteries
(1) Removal of the FDIMU Batteries:
(a) Loosen the captive screws (1) on the battery housing cover (2) on the rear panel of the unit.
(b) Remove the battery housing cover (2).
(c) Remove the batteries (3).
(2) Installation of the FDIMU Batteries:
(a) Install the new batteries (3) in the rear of the unit. Make sure the polarity (+/-) is correct.
(b) Put the battery housing cover (2) in position on the rear of the unit.
(c) Tighten the captive screws (1).
5. Close-up(1) Removal of the FDIMU Batteries:
(a) Loosen the captive screws (1) on the battery housing cover (2) on the rear panel of the unit.
(b) Remove the battery housing cover (2).
(c) Remove the batteries (3).
(2) Installation of the FDIMU Batteries:
(a) Install the new batteries (3) in the rear of the unit. Make sure the polarity (+/-) is correct.
(b) Put the battery housing cover (2) in position on the rear of the unit.
(c) Tighten the captive screws (1).
Subtask 31-36-00-400-054-A ** ON A/C NOT FOR ALL Subtask 31-36-00-710-081-A ** ON A/C NOT FOR ALL Subtask 31-36-00-410-067-A ** ON A/C NOT FOR ALL
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).