Replacement of the DMU Batteries
TASK 31-36-00-960-002-A
Replacement of the DMU Batteries
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-00-865-079-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-960-050-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-400-053-A ** ON A/C NOT FOR ALL Subtask 31-36-00-410-065-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:35:56 UTC
Replacement of the DMU Batteries
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 31-36-00-710-001-A | Test of the DMU |
| TASK 31-36-34-000-001-A | Removal of the Data Management Unit (DMU) |
| TASK 31-36-34-400-001-A | Installation of the Data Management Unit (DMU) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-36-00-865-079-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 31-36-00-010-066-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS/DMU | 4TV | K15 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 824.
(2) Open the access door 824. (Ref. AMM TASK 52-41-00-010-002)
Subtask 31-36-00-000-053-A ** ON A/C NOT FOR ALL 4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 824.
(2) Open the access door 824. (Ref. AMM TASK 52-41-00-010-002)
Subtask 31-36-00-960-050-A ** ON A/C NOT FOR ALL
A. Replacement of DMU Batteries
(1) Removal of the DMU batteries:
(a) Loosen the 2 captive screws on the battery housing cover on the rear panel of the unit.
(b) Remove the battery housing cover.
(c) Remove the batteries.
(2) Installation of the DMU batteries:
(a) Put the new batteries into the space provided in the rear of the unit. Make sure the polarity (+/-) is correct.
(b) Put the battery housing cover in the location provided on the rear of the unit.
(c) Attach the 2 captive screws on the battery housing cover.
5. Close-up(1) Removal of the DMU batteries:
(a) Loosen the 2 captive screws on the battery housing cover on the rear panel of the unit.
(b) Remove the battery housing cover.
(c) Remove the batteries.
(2) Installation of the DMU batteries:
(a) Put the new batteries into the space provided in the rear of the unit. Make sure the polarity (+/-) is correct.
(b) Put the battery housing cover in the location provided on the rear of the unit.
(c) Attach the 2 captive screws on the battery housing cover.
Subtask 31-36-00-400-053-A ** ON A/C NOT FOR ALL Subtask 31-36-00-410-065-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
Subtask 31-36-00-710-072-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
Replacement of the DMU Batteries