W DOC AIRBUS | AMM A320F

Replacement of the DMU Batteries


TASK 31-36-00-960-002-A
Replacement of the DMU Batteries


ZONE: 128
ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
128
REAR AVIONIC COMPARTMENT
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-36-00-710-001-A
Test of the DMU
TASK 31-36-34-000-001-A
Removal of the Data Management Unit (DMU)
TASK 31-36-34-400-001-A
Installation of the Data Management Unit (DMU)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 31-36-00-865-079-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAIDS/DMU4TVK15
Subtask 31-36-00-010-066-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 824.
   (2) Open the access door 824. (Ref. AMM TASK 52-41-00-010-002)
Subtask 31-36-00-000-053-A ** ON A/C NOT FOR ALL
C. Remove the DMU (Ref. AMM TASK 31-36-34-000-001).
4. Procedure
Subtask 31-36-00-960-050-A ** ON A/C NOT FOR ALL
A. Replacement of DMU Batteries
F Replacement of the DMU Batteries ** ON A/C NOT FOR ALL
   (1) Removal of the DMU batteries:

     (a) Loosen the 2 captive screws on the battery housing cover on the rear panel of the unit.

     (b) Remove the battery housing cover.

     (c) Remove the batteries.

   (2) Installation of the DMU batteries:

     (a) Put the new batteries into the space provided in the rear of the unit. Make sure the polarity (+/-) is correct.

     (b) Put the battery housing cover in the location provided on the rear of the unit.

     (c) Attach the 2 captive screws on the battery housing cover.

5. Close-up
Subtask 31-36-00-400-053-A ** ON A/C NOT FOR ALL
A. Install the DMU (Ref. AMM TASK 31-36-34-400-001).
Subtask 31-36-00-410-065-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
   (3) Remove the access platform(s).
Subtask 31-36-00-710-072-A ** ON A/C NOT FOR ALL
C. Operational test of the DMU (Ref. AMM TASK 31-36-00-710-001).
[Rev.10 from 2021] 2026.04.01 00:35:56 UTC