Dump Procedure to Download the FDIMU Data
TASK 31-36-00-710-014-A
Dump Procedure to Download the FDIMU Data
1. Reason for the Job
This procedure contains the download of SAR/REPORT-files, which are stored in the non-volatile Solid-State Mass Memory (SSMM).
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 31-36-00-860-095-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-710-082-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-410-068-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:35:43 UTC
Dump Procedure to Download the FDIMU Data
1. Reason for the Job
This procedure contains the download of SAR/REPORT-files, which are stored in the non-volatile Solid-State Mass Memory (SSMM).
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | DISK - DATA |
| YV68A110 | 1 | PORTABLE DATA LOADER |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | adapter cable |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-36-00-860-095-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(Ref. AMM TASK 24-41-00-861-002)
(2) On the front panel of the FDIMU, open the flap to get access to the FDIMU front connector.
(3) On the YV68A110 PORTABLE DATA LOADER make sure that the ON/OFF switch is in the OFF position.
(4) Connect the adapter cable to the FDIMU front connector.
(5) Connect the adapter cable to the PDL interface.
(6) Make sure that the DISK - DATA is not write-protected.
Subtask 31-36-00-860-097-A ** ON A/C NOT FOR ALL NOTE: This task is only applicable for data download through the PDL.
NOTE: For the download procedure a 1,44 MB formatted 3,5 inch disk is necessary. This disk must be prepared by the GSE Application Software. Refer to the software vendor documentation.
(1) Energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-861-002)
(2) On the front panel of the FDIMU, open the flap to get access to the FDIMU front connector.
(3) On the YV68A110 PORTABLE DATA LOADER make sure that the ON/OFF switch is in the OFF position.
(4) Connect the adapter cable to the FDIMU front connector.
(5) Connect the adapter cable to the PDL interface.
(6) Make sure that the DISK - DATA is not write-protected.
B. Aircraft Maintenance Configuration
(Ref. AMM TASK 24-41-00-861-002)
(2) Make sure that the disk is not write-protected.
Subtask 31-36-00-010-069-A ** ON A/C NOT FOR ALL NOTE: This task is only applicable for data download through the MDDU.
NOTE: For the download procedure a 1,44 MB formatted 3,5 inch disk is necessary. This disk must be prepared by the GSE Application Software (Ref. software vendor documentation).
(1) Energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-861-002)
(2) Make sure that the disk is not write-protected.
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position, at the access door 824, in zone 128.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-36-00-865-097-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position, at the access door 824, in zone 128.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
D. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
| 121VU | DATA/LOADER/SPLY | 3TD | J16 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
| 121VU | ENGINE/ENG1 AND 2/EVMU | 1EV | R44 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DLS&/DLRB/SPLY | 5TD | J15 |
Subtask 31-36-00-710-082-A ** ON A/C NOT FOR ALL
A. Dump Procedure to Download the FDIMU Data through the PDL
Subtask 31-36-00-710-083-A ** ON A/C NOT FOR ALL NOTE: This task is only applicable for data download through the PDL.
| ACTION | RESULT |
|---|---|
| 1.On the Portable Data Loader (PDL): | On the PDL display: |
|
|
|
|
|
|
|
|
| |
B. Dump Procedure to Download the FDIMU Data through the MDDU
5. Close-upNOTE: This task is only applicable for data download through the MDDU.
| ACTION | RESULT |
|---|---|
| 1.On the overhead panel, on Data Loading Selector 101TD: | On the Data Loading Selector display: |
|
|
|
|
|
|
| 2.On the Center Pedestal, on the MDDU: | On the MDDU display: |
|
|
|
|
NOTE: For some MDDU P/N the BUS-number and the file-sizes show between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading. | |
|
|
|
|
| |
| 3.On the Data Loading Selector: | On the Data Loading Selector display: |
|
|
| |
Subtask 31-36-00-410-068-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 31-36-00-860-096-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
B. Aircraft Maintenance Configuration after Dump Procedure to Download the FDIMU Data through the PDL
(Ref. AMM TASK 24-41-00-862-002).
(2) Disconnect the adapter cable from the FDIMU.
(3) Disconnect the adapter cable from the PDL.
(4) On the FDIMU close the flap.
Subtask 31-36-00-860-098-A ** ON A/C NOT FOR ALL NOTE: This task is only applicable for data download through the PDL.
(1) De-energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-862-002).
(2) Disconnect the adapter cable from the FDIMU.
(3) Disconnect the adapter cable from the PDL.
(4) On the FDIMU close the flap.
C. Aircraft Maintenance Configuration after Dump Procedure to Download the FDIMU Data through the MDDU
(Ref. AMM TASK 24-41-00-862-002).
NOTE: This task is only applicable for data download through the MDDU.
(1) De-energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-862-002).