W DOC AIRBUS | AMM A320F

FDIMU AIDS Software Load Procedure with the MDDU


TASK 31-36-00-710-013-A-01
FDIMU AIDS Software Load Procedure with the MDDU


ZONE: 120
ZONE: 210
FIN: 10TV ** ON A/C NOT FOR ALL
FIN: 10TV2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-36-00-740-012-A
Test of the Flight Data Interface and Management Unit (FDIMU)
TASK 31-36-00-740-013-A
Update of the APU Hours and Cycles in the FDIMU after APU, ECB or FDIMU Replacement
TASK 31-36-00-740-014-A
Update of the Engine Hours and Cycles in the Flight Data Interface and Management Unit (FDIMU)
TASK 31-36-00-740-015-A
Printout of the Engine/APU Hours and Cycles Stored in the Flight Data Interface and Management Unit (FDIMU)
3. Job Set-up
Subtask 31-36-00-860-126-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do a print out of the engine and APU hours and cycles (Ref. AMM TASK 31-36-00-740-015).
NOTE: The software load can erase the data of the engine and APU hours and cycles in the FDIMU. The print out gives a hard copy of this data. Use the print out as a reference to correct the engine and APU hours and cycles later, if necessary.
All modifications previously done through MCDU programming menu may be lost after the software loading. Reports counters will be also reinitialized.
   (3) Make sure that the aircraft is in Ground configuration (Landing Gear compressed and all Engines stopped).
   (4) On the front panel of the FDIMU open the flap to get access to the OPERATIONAL/STORAGE switch.
   (5) Make sure that the OPERATIONAL ON/OFF switch is in the ON position.
NOTE: This lets the battery backup buffering of all internal AIDS data stored in the volatile memory in case of external power shut-down.
   (6) Make sure that [10TV2] are in writeprotected status (writeprotection ON).
   (7) Make sure that [10TV3] are in writeprotected status (writeprotection ON).
NOTE: Depending on the software version the number of disks can change.
Subtask 31-36-00-860-126-C ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do a print out of the engine and APU hours and cycles (Ref. AMM TASK 31-36-00-740-015).
NOTE: The software load can erase the data of the engine and APU hours and cycles in the FDIMU. The print out gives a hard copy of this data. Use the print out as a reference to correct the engine and APU hours and cycles later, if necessary.
All modifications previously done through MCDU programming menu can be lost after the software loading. Reports counters will be also reinitialized.
   (3) Make sure that the aircraft is in Ground configuration (Landing Gear compressed and all Engines stopped).
   (4) On the front panel of the FDIMU open the flap to get access to the OPERATIONAL/STORAGE switch.
   (5) Make sure that the OPERATIONAL ON/OFF switch is in the ON position.
NOTE: This enables the battery backup buffering of all internal AIDS data stored in the volatile memory in case of external power shut-down.
   (6) Make sure that the [10TVMD2] with the [10TVSW2] are in the writeprotected status (writeprotection ON).
   (7) Make sure that the [10TVMD3] with the [10TVSW3] are in the writeprotected status (writeprotection ON).
NOTE: Depending on the software version the number of disks can change.
Subtask 31-36-00-860-126-CT
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do a print out of the engine and APU hours and cycles (Ref. AMM TASK 31-36-00-740-006) or (Ref. AMM TASK 31-36-00-740-015).
NOTE: The software load can erase the data of the engine and APU hours and cycles in the FDIMU. The print out gives a hard copy of this data. Use the print out as a reference to correct the engine and APU hours and cycles later, if necessary.
All modifications previously done through MCDU programming menu can be lost after the software loading. Reports counters are also set to the initial condition.
   (3) Make sure that the aircraft is in ground configuration (landing gear compressed and all engines stopped).
   (4) On the front panel of the FDIMU, open the flap to get access to the OPERATIONAL/STORAGE switch.
   (5) Make sure that the OPERATIONAL ON/OFF switch is in the ON position.
NOTE: This enables the battery backup buffering of all internal AIDS data stored in the volatile memory in case of external power shut-down.
   (6) Make sure that [10TVMD5] with [10TVSW5] are in the writeprotected status (writeprotection ON).
   (7) Make sure that [10TVMD6] with [10TVSW6] are in the writeprotected status (writeprotection ON).
   (8) Make sure that [10TVMD7] with [10TVSW7] are in the writeprotected status (writeprotection ON).
   (9) Make sure that [10TVMD8] with [10TVSW8] are in the writeprotected status (writeprotection ON).
   (10) Make sure that [10TVMD9] with [10TVSW9] are in the writeprotected status (writeprotection ON).
NOTE: Depending on the software version the number of disks can change.
Subtask 31-36-00-865-158-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
121VUDATA/LOADER/SPLY3TDJ16
121VUAIDS & RCDR/FDIMU5TVK15
121VUENGINE/ENG1 AND 2/EVMU1EVR44
** ON A/C NOT FOR ALL
121VUDLS&/DLRB/SPLY5TDJ15
4. Procedure
Subtask 31-36-00-710-152-E
A. Set-Up System Software Load Procedure
   (1) Upload the FINs in this sequence:
  • 10TV SW5
  • 10TV SW6
  • 10TV SW7
  • 10TV SW8
  • 10TV SW9.
Subtask 31-36-00-710-124-A ** ON A/C NOT FOR ALL
B. System Software Load Procedure
NOTE: The standard vendor system-software is available on three disks:
  • Disk 1/3 is for an A/C equipped with IAE engines.
  • Disk 2/3 is for an A/C equipped with CFMI engines and standard EVMU.
  • Disk 3/3 is for an A/C equipped with CFMI engines and advanced EVMU.
For this procedure use only the disk which is applicable for the on A/C installed engine type.
NOTE: The software part number is shown in the IPC.
ACTION
RESULT
On the overhead panel, on the Data Loading Selector (DLS):
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
  • Put the [10TV2] into the MDDU.
NOTE: Each software version has a specified number of disks. It is necessary to load all disks until the loading process is completed.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • Push the EJECT button and remove the [10TV2] .
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Set the ON/OFF switch to the OFF position.

On the MCDU:
On the MCDU display:
  • Push the MCDU MENU mode key.
  • The AIDS prompt must show.
Subtask 31-36-00-710-125-A ** ON A/C NOT FOR ALL
C. Set-Up Database Software Load Procedure
NOTE: The standard vendor database-software is available on three disks:
  • Disk 1/3 is for an A/C equipped with IAE engines.
  • Disk 2/3 is for an A/C equipped with CFMI engines and standard EVMU.
  • Disk 3/3 is for an A/C equipped with CFMI engines and advanced EVMU.
For this procedure use only the disk which is applicable for the on A/C installed engine type.
NOTE: The software part number is shown in the IPC.
NOTE: The upload of the database files can be monitored on the MCDU in the AIDS menu LOAD STATUS page.
ACTION
RESULT
On the overhead panel, on the DLS:
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
  • Put the [10TV3] into the MDDU.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • Push the EJECT button and remove the [10TV3] .
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

  • Set the ON/OFF switch to the OFF position.
  • The ON/OFF switch is in the OFF position.
Subtask 31-36-00-710-124-C ** ON A/C NOT FOR ALL
D. System Software Load Procedure
NOTE: The standard vendor system-software is available on three disks:
  • Disk 1/3 is for an A/C equipped with IAE engines.
  • Disk 2/3 is for an A/C equipped with CFMI engines and standard EVMU.
  • Disk 3/3 is for an A/C equipped with CFMI engines and advanced EVMU.
For this procedure use only the disk which is applicable for the on A/C installed engine type.
NOTE: The software part number is shown in the IPC.
ACTION
RESULT
On the overhead panel, on the Data Loading Selector (DLS):
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
NOTE: Each software version has a specified number of disks. It is necessary to load all disks until the loading process is completed.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: Some MDDUs show the BUS number and the file sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Set the ON/OFF switch to the OFF position.

On the MCDU:
On the MCDU display:
  • Push the MCDU MENU mode key.
  • The AIDS prompt show.
Subtask 31-36-00-710-125-C ** ON A/C NOT FOR ALL
E. Set-Up Database Software Load Procedure
NOTE: The standard vendor database-software is available on three disks:
  • Disk 1/3 is for an A/C equipped with IAE engines.
  • Disk 2/3 is for an A/C equipped with CFMI engines and standard EVMU.
  • Disk 3/3 is for an A/C equipped with CFMI engines and advanced EVMU.
For this procedure use only the disk which is applicable for the on A/C installed engine type.
NOTE: The software part number is shown in the IPC.
NOTE: The upload of the database files can be monitored on the MCDU in the AIDS menu LOAD STATUS page.
ACTION
RESULT
On the overhead panel, on the DLS:
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: On some MDDUs, the display shows the BUS-number and the file sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.
  • The floppy disk access door is closed.
On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Set the ON/OFF switch to the OFF position.
  • The ON/OFF switch is in the OFF position.
Subtask 31-36-00-710-124-E ** ON A/C NOT FOR ALL
F. System Software Load Procedure
NOTE: The software part number is shown in the IPC.
ACTION
RESULT
On the overhead panel, on the Data Loading Selector:
On the Data Loading Selector display:
  • Put the data ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the Center Pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
NOTE: Depending on the software version the number of disks can change. Load all disks until the loading process is completed.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: Some MDDUs show the BUS number and the file sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the Data Loading Selector panel:
On the Data Loading Selector display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Set the ON/OFF switch to OFF.

On the MCDU:
On the MCDU display:
  • Push the MCDU MENU mode key.
  • The AIDS prompt show.
Subtask 31-36-00-710-125-B ** ON A/C NOT FOR ALL
G. Set-Up Database Software Load Procedure
NOTE: The software part number is shown in the IPC.
NOTE: You can monitor on the MCDU in the AIDS menu LOAD STATUS page the upload of the database files.
ACTION
RESULT
On the overhead panel, on the Data Loading Selector:
On the Data Loading Selector display:
  • Put the data loading selector ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Push the SEL CTL key.
  • The AIDS SELECTED indication shows.

NOTE: The display can show AIDS SELECTED or ACMS SELECTED.

On the Center Pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.

NOTE: On some MDDUs, the display shows the BUS-number and the file sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the data loading.

  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.
  • The floppy disk access door is closed.
On the Data Loading Selector panel:
On the Data Loading Selector display:
  • Push the SEL CTL key.
  • The AIDS NOT SELECTED indication shows.

NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.

  • Set the ON/OFF switch to OFF.
  • The ON/OFF switch is in the OFF position.
Subtask 31-36-00-710-124-CT
H. System Software Load Procedure
ACTION
RESULT
On the overhead panel, on the Data Loading Selector (DLS):
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.
  • The AIDS NOT SELECTED indication shows.
  • Push the SEL CTL key.
NOTE: The display can show AIDS SELECTED or ACMS SELECTED.
  • The AIDS SELECTED indication shows.
On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
NOTE: Each software version has a specified number of disks. It is necessary to load all disks until the loading process is completed.
NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.
  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.
  • The AIDS NOT SELECTED indication shows.
  • Set the ON/OFF switch to OFF.

On the MCDU:
On the MCDU display:
  • Push the MCDU MENU mode key.
  • The AIDS prompt must show.
Subtask 31-36-00-710-125-CT
I. Set-Up Database Software Load Procedure
ACTION
RESULT
On the overhead panel, on the DLS:
On the DLS display:
  • Put the ON/OFF switch to the ON position.
  • The DB/N:XXXXXXXX and PUSH NEXT/PREV indications show.
  • Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.
  • The ACMS NOT SELECTED indication shows.
  • Push the SEL CTL key.
NOTE: The display can show AIDS SELECTED or ACMS SELECTED.
  • The ACMS SELECTED indication shows.
On the center pedestal, on the MDDU:
On the MDDU display:
  • Open the floppy disk access door.
  • The MDDU READY indication shows.
NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.
  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.
  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.
  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
NOTE: Some MDDUs show the BUS-number and the file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the progress of the data loading.
  • These indications show in a short time:
    READY
    WAIT RESPONSE
    TRANSF IN PROG.
  • Wait until the TRANSF COMPLETE indication comes on.
  • The TRANSF COMPLETE indication shows after the load procedure is completed correctly.
  • The MDDU READY indication shows.
  • Close the floppy disk access door.

On the DLS panel:
On the DLS display:
  • Push the SEL CTL key.
NOTE: The display can show AIDS NOT SELECTED or ACMS NOT SELECTED.
  • The AIDS NOT SELECTED indication shows.
  • Set the ON/OFF switch to the OFF position.
  • The ON/OFF switch is in the OFF position.
Subtask 31-36-00-970-051-A ** ON A/C NOT FOR ALL
J. Do a Check of the Part Number of the FDIMU Software
ACTION
RESULT
On the MCDU:
On the MCDU display:
  • Push the line key adjacent to the AIDS indication.
  • The AIDS page comes into view.
  • Push the line key adjacent to the PROGRAMMING indication.
  • The AIDS DMU PROGRAMMING page comes into view.
  • Make sure that the FDIMU software part-number and FDIMU hardware part-number are correct.

  • Push the line key adjacent to the RETURN indication.
  • The AIDS page comes into view.
  • Push the line key adjacent to the STOP indication.
  • The MCDU MENU page comes into view.
Subtask 31-36-00-970-051-CT
J. Do a Check of the Part Number of the FDIMU Software
ACTION
RESULT
On the MCDU:
On the MCDU display:
  • Push the line key adjacent to the AIDS indication.
  • The AIDS page comes into view.
  • Push the line key adjacent to the PROGRAMMING indication.
  • The AIDS DMU PROGRAMMING page (1 of 3) comes into view.
  • Make sure that the ACMS core software part-number, DMU engine software part-number, DMU set-up database part-number and FDIMU hardware part-number are correct.

  • Push the MCDU key page down.
  • The AIDS DMU PROGRAMMING page (2 of 3) comes into view.
  • Make sure that the Config file A information is correct.

  • Push the MCDU key page down.
  • The AIDS DMU PROGRAMMING page (3 of 3) comes into view.
  • Make sure that the Config file B information is correct.

  • Push the line key adjacent to the RETURN indication.
  • The AIDS DMU PROGRAMMING page comes into view.
  • Push the line key adjacent to the RETURN indication.
  • The AIDS page comes into view.
  • Push the line key adjacent to the STOP indication.
  • The MCDU MENU page comes into view.
5. Close-up
Subtask 31-36-00-710-126-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the test of the FDIMU (Ref. AMM TASK 31-36-00-740-012).
Subtask 31-36-00-860-127-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) If necessary do an update of the engine and APU hours and cycles (Ref. AMM TASK 31-36-00-740-013) and (Ref. AMM TASK 31-36-00-740-014).
NOTE: The update is necessary if the software load erases the data of the engine and APU hours and cycles in the FDIMU.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).