Replacement of the Cassette with the QAR not Energized
TASK 31-33-52-600-006-A
Replacement of the Cassette with the QAR not Energized
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-52-020-056-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-410-058-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.01 00:35:00 UTC
Replacement of the Cassette with the QAR not Energized
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
NOTE: If the sticker of the cassette is in incorrect position, the QAR does not operate. Thus we recommend the replacement of the cassette with the QAR energized.
Subtask 31-33-52-865-059-A ** ON A/C NOT FOR ALL A. Open, safety and tag this(these) circuit breaker(s):
Subtask 31-33-52-010-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 31-33-52-020-056-A ** ON A/C NOT FOR ALL
A. Removal of the Cassette
(1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
(2) Lift and pull the cassette extraction/locking lever (3) to eject the cassette (2).
(3) Remove the cassette (2).
(4) Lower the extraction/locking lever (3).
(5) Close the door (4) and lock it with the two wing nuts (5).
Subtask 31-33-52-420-056-A ** ON A/C NOT FOR ALL (1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
(2) Lift and pull the cassette extraction/locking lever (3) to eject the cassette (2).
(3) Remove the cassette (2).
(4) Lower the extraction/locking lever (3).
(5) Close the door (4) and lock it with the two wing nuts (5).
B. Installation of the Cassette
(1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
(2) Lift the cassette extraction/locking lever (3).
(3) Make sure that the BOT (Beginning Of Tape) warning sticker is in front of the reflector of the cassette.
(4) Install the cassette (2) with the shutter protection on the extraction/locking lever side.
(5) Push the cassette (2) fully in until it engages correctly in its chamber.
(6) Lower the extraction/locking lever (3).
(7) Close the door (4) and lock it with the two wing nuts (5).
Subtask 31-33-52-861-055-A ** ON A/C NOT FOR ALL Subtask 31-33-52-865-060-A ** ON A/C NOT FOR ALL (1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
(2) Lift the cassette extraction/locking lever (3).
(3) Make sure that the BOT (Beginning Of Tape) warning sticker is in front of the reflector of the cassette.
(4) Install the cassette (2) with the shutter protection on the extraction/locking lever side.
(5) Push the cassette (2) fully in until it engages correctly in its chamber.
(6) Lower the extraction/locking lever (3).
(7) Close the door (4) and lock it with the two wing nuts (5).
NOTE: At the energization of the QAR, the BOT sensing device automatically sets the track 1.
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-33-52-210-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
E. Make sure that the FIRST TRACK light (2) on the QAR is on.
5. Close-upNOTE: If the FIRST TRACK light (2) is not on, do the procedure with the QAR energized.
Subtask 31-33-52-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Subtask 31-33-52-862-055-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
QAR Cassette