W DOC AIRBUS | AMM A320F

Replacement of the Cassette with the QAR Energized


TASK 31-33-52-600-005-A
Replacement of the Cassette with the QAR Energized


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 127
FIN: 3TU ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 31-33-52-861-054-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-33-52-865-058-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
Subtask 31-33-52-010-056-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
   (2) Open the access door 824.
4. Procedure
Subtask 31-33-52-020-055-A ** ON A/C NOT FOR ALL
A. Removal of the Cassette
   (1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
   (2) Lift and pull the cassette extraction/locking lever (3) to eject the cassette (2).
   (3) Remove the cassette (2).
   (4) Lower the extraction/locking lever (3).
   (5) Close the door (4) and lock it with the two wing nuts (5).

NOTE: The removal of the cassette does not cause track reset.
Subtask 31-33-52-420-055-A ** ON A/C NOT FOR ALL
B. Installation of the Cassette
   (1) Loosen the two wing nuts (5) and open the door (4) of the QAR.
   (2) Lift the cassette extraction/locking lever (3).
   (3) Install the cassette (2) with the shutter protection on the extraction/locking lever side.
   (4) Push the cassette (2) fully in until it engages correctly in its chamber.
   (5) Lower the extraction/locking lever (3).
   (6) Close the door (4) and lock it with the two wing nuts (5).

NOTE: The installation of the cassette automatically sets the track 1. This track number is kept in a non-volatile memory. The position of the sticker is not important.
5. Close-up
Subtask 31-33-52-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824.
   (3) Remove the access platform(s).
Subtask 31-33-52-862-054-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.9 from 2019] 2026.04.02 06:20:28 UTC