Replacement of the Disk with the QAR Energized
TASK 31-33-52-600-004-A
Replacement of the Disk with the QAR Energized
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-52-861-053-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-020-054-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-410-056-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.01 00:34:58 UTC
Replacement of the Disk with the QAR Energized
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 31-33-52-861-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-33-52-865-057-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-33-52-010-059-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824.
Subtask 31-33-52-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Disk
(1) On the QAR, make sure that the ON indicator light (2) is on.
(2) Turn the two fasteners (7) and open the door (8) of the QAR.
(3) Remove the disk (9).
The STATUS warning light (4) is on.
(4) Close the door (8) and lock it with the two fasteners (7).
Subtask 31-33-52-420-054-A ** ON A/C NOT FOR ALL (1) On the QAR, make sure that the ON indicator light (2) is on.
(2) Turn the two fasteners (7) and open the door (8) of the QAR.
(3) Remove the disk (9).
The STATUS warning light (4) is on.
(4) Close the door (8) and lock it with the two fasteners (7).
B. Installation of the Disk
(2) Put the disk (9) in the disk drive (the arrow on the disk must be on the left side).
(3) Push the disk (9) fully in until it engages correctly in its chamber.
(4) Close the door (8) and lock it with the two fasteners (7).
(5) The DISK LOW warning light (3) is on if the storage capacity is lower than 35 per cent.
5. Close-upNOTE: You can put a disk into the disk drive only if the QAR is energized.
If there is no disk in the disk drive, the STATUS warning light (4) is on.
(1) Turn the two fasteners (7) and open the door (8) of the QAR. If there is no disk in the disk drive, the STATUS warning light (4) is on.
(2) Put the disk (9) in the disk drive (the arrow on the disk must be on the left side).
(3) Push the disk (9) fully in until it engages correctly in its chamber.
(4) Close the door (8) and lock it with the two fasteners (7).
(5) The DISK LOW warning light (3) is on if the storage capacity is lower than 35 per cent.
NOTE: If there is a fault, the STATUS warning light (4) stays on.
Subtask 31-33-52-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Subtask 31-33-52-862-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
QAR Disk