W DOC AIRBUS | AMM A320F

Installation of the Wireless Ground Link Quick Access Recorder (WGL-QAR)


TASK 31-33-52-400-002-A
Installation of the Wireless Ground Link Quick Access Recorder (WGL-QAR)


ZONE: 127
FIN: 3TU ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-33-00-710-018-A
Update of the Aircraft Tail Number in the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
TASK 31-33-00-710-021-A
Operational Test of the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
TASK 31-33-00-710-805-A
Update of the Wireless Ground Link-Quick Access Recorder (WGL-QAR) Date and Time
TASK 31-33-00-710-807-A
Upload Procedure and Part Number Verification of the Loadable Software Parts (LSP) in the Wireless Ground Link-Quick Access Recorder (WGL-QAR)
TASK 31-33-00-960-801-A
Replacement of the Compact Flash Card of the WGL-QAR
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 31-33-52-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position below access door 824 at zone 128.
   (2) Make sure that access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-33-52-875-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/QAR14TUK17
4. Procedure
Subtask 31-33-52-420-058-B ** ON A/C NOT FOR ALL
A. Installation of the WGL-QAR
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Put the WGL-QAR (1) in position on the rack (2).
   (6) Push the WGL-QAR (1) on its rack (2) to connect the electrical connector (5).
   (7) Engage the nuts (3) on the lugs (4) and tighten them.
   (8) For the WGL-QAR with only the compact flash-card option, make sure that the compact flash card is installed (Ref. AMM TASK 31-33-00-960-801).
Subtask 31-33-52-875-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/QAR14TUK17
Subtask 31-33-52-710-053-A ** ON A/C NOT FOR ALL
C. Do the operational test of the WGL-QAR (Ref. AMM TASK 31-33-00-710-021).
Subtask 31-33-52-710-054-C ** ON A/C NOT FOR ALL
D. Do the steps that follow:
   (1) Do the update of the WGL-QAR date and time (Ref. AMM TASK 31-33-00-710-805).
   (2) Do the update of the aircraft tail number in the WGL-QAR (Ref. AMM TASK 31-33-00-710-018).
   (3) Do the upload procedure and part number verification of the loadable software parts in the WGL-QAR (Ref. AMM TASK 31-33-00-710-807).
5. Close-up
Subtask 31-33-52-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
   (3) Remove the access platform(s).

[Rev.10 from 2021] 2026.04.01 00:35:02 UTC