Installation of the Quick Access Recorder (QAR)
TASK 31-33-52-400-001-A
Installation of the Quick Access Recorder (QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-52-860-050-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-420-050-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-410-050-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.01 00:35:04 UTC
Installation of the Quick Access Recorder (QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 31-33-00-710-005-A | Operational Test of the Quick Access Recorder (QAR) |
| TASK 31-36-00-400-001-A | Installation of the Personal Computer Memory Card (PCMCIA) of the FDIMU/DMU |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 31-33-52-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-33-52-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
Subtask 31-33-52-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Quick Access Recorder (QAR)
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2).
(4) Make sure that the electrical connectors (2) are clean and in the correct condition.
(5) Install the QAR (1) on its rack (3).
(6) Push the QAR (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
(8) For QAR with PCMCIA card option only, make sure that the PCMCIA card is installed (Ref. AMM TASK 31-36-00-400-001).
Subtask 31-33-52-865-052-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2).
(4) Make sure that the electrical connectors (2) are clean and in the correct condition.
(5) Install the QAR (1) on its rack (3).
(6) Push the QAR (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nuts (4) on the lugs (5) and tighten.
(8) For QAR with PCMCIA card option only, make sure that the PCMCIA card is installed (Ref. AMM TASK 31-36-00-400-001).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-33-52-710-051-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
Subtask 31-33-52-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
Quick Access Recorder (QAR)