Installation of the Quick Access Recorder (QAR)


TASK 31-33-52-400-001-A
Installation of the Quick Access Recorder (QAR)


ZONE: 127
FIN: 3TU ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-33-00-710-005-A
Operational Test of the Quick Access Recorder (QAR)
TASK 31-36-00-400-001-A
Installation of the Personal Computer Memory Card (PCMCIA) of the FDIMU/DMU
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 31-33-52-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 824 in zone 128.
   (2) Make sure that the access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-33-52-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/QAR14TUK17
4. Procedure
Subtask 31-33-52-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Quick Access Recorder (QAR)
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking caps from the electrical connectors (2).
   (4) Make sure that the electrical connectors (2) are clean and in the correct condition.
   (5) Install the QAR (1) on its rack (3).
   (6) Push the QAR (1) on its rack (3) to connect the electrical connectors (2).
   (7) Engage the nuts (4) on the lugs (5) and tighten.
   (8) For QAR with PCMCIA card option only, make sure that the PCMCIA card is installed (Ref. AMM TASK 31-36-00-400-001).
Subtask 31-33-52-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/QAR14TUK17
Subtask 31-33-52-710-051-A ** ON A/C NOT FOR ALL
C. Do the operational test of the QAR (If installed) (Ref. AMM TASK 31-33-00-710-005).
5. Close-up
Subtask 31-33-52-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 824. (Ref. AMM TASK 52-41-00-410-002)
   (3) Remove the access platform(s).