Removal of the Wireless Ground Link Quick Access Recorder (WGL-QAR)
TASK 31-33-52-000-002-A
Removal of the Wireless Ground Link Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-52-010-060-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-020-058-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:35:01 UTC
Removal of the Wireless Ground Link Quick Access Recorder (WGL-QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 31-33-52-010-060-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in zone 128, at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-33-52-875-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in zone 128, at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
Subtask 31-33-52-020-058-B ** ON A/C NOT FOR ALL
A. Removal of the Wireless Ground Link Quick Access Recorder (WGL-QAR)
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the WGL-QAR (1) on its rack (2) to disconnect the electrical connector(s) (5).
(4) Remove the WGL-QAR (1) from its rack (2).
(5) Put blanking cap(s) on the disconnected electrical connector(s) (5).
(1) Loosen the nuts (3).
(2) Lower the nuts (3).
(3) Pull the WGL-QAR (1) on its rack (2) to disconnect the electrical connector(s) (5).
(4) Remove the WGL-QAR (1) from its rack (2).
(5) Put blanking cap(s) on the disconnected electrical connector(s) (5).
Wireless Ground Link Quick Access Recorder (WGL-QAR)