Removal of the Quick Access Recorder (QAR)
TASK 31-33-52-000-001-A
Removal of the Quick Access Recorder (QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-52-010-050-A ** ON A/C NOT FOR ALL
Subtask 31-33-52-020-050-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.01 00:35:03 UTC
Removal of the Quick Access Recorder (QAR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 31-33-52-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in zone 128, at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-33-52-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in zone 128, at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
Subtask 31-33-52-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Quick Access Recorder (QAR)
(1) Loosen the nuts (4).
(2) Lower the nuts (4).
(3) Pull the QAR (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the QAR (1) from its rack (3).
(5) Put blanking caps on the disconnected electrical connectors (2).
(1) Loosen the nuts (4).
(2) Lower the nuts (4).
(3) Pull the QAR (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the QAR (1) from its rack (3).
(5) Put blanking caps on the disconnected electrical connectors (2).
Quick Access Recorder (QAR)