Operational Check of ULB
TASK 31-33-00-710-015-A
Operational Check of ULB
Refer to the MPD TASK: 313300-03
OPERATIONAL CHECK OF ULB
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 31-33-00-010-061-A ** ON A/C NOT FOR ALL
Subtask 31-33-00-860-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:34:45 UTC
Operational Check of ULB
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 312
1. Reason for the JobRefer to the MPD TASK: 313300-03
OPERATIONAL CHECK OF ULB
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | ELECTRICAL LEAD |
| 42A12-1 | 1 | ULTRASONIC TEST SET (42A12-1) |
| TS200 | 1 | ULTRASONIC TEST SET (TS200) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBV9) | Non Aqueous Cleaner-- Trichlorotrifluoroethane Legacy |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 312 | AFT FUSLG TAIL SECTION |
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 31-33-55-920-001-A | Discard the Underwater Locator Beacon (ULB) Battery |
Subtask 31-33-00-010-061-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position at the zone 312.
(2) Open the access door 312AR.
Subtask 31-33-00-860-058-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position at the zone 312.
(2) Open the access door 312AR.
B. Aircraft Maintenance Configuration
(2) If you use the 42A12-1 ULTRASONIC TEST SET (42A12-1):
4. ProcedureNOTE: For this procedure you can use ULTRASONIC TEST SET part number (P/N) 42A12 or equivalent.
(1) On the ULB, look at the date on the battery replacement label. If the date is expired, replace the battery (Ref. AMM TASK 31-33-55-920-001). (2) If you use the 42A12-1 ULTRASONIC TEST SET (42A12-1):
- If necessary, set the INPUT switch to INT
- Set the TUNING potentiometer to between 30KHz and 45KHz
- Set the GAIN potentiometer to the maximum position.
- Make a short circuit between the ULB water switch and the battery body with an ELECTRICAL LEAD.
- Put the microphone of the ultrasonic test set as near as possible to the ULB.
Tune the ultrasonic test set to get the best signal.
- Turn the ULTRASONIC TEST SET (TS200) ON with the switch from the left side of the housing.
NOTE: It is necessary to select the applicable procedure for the test tool you use.
Subtask 31-33-00-710-099-A ** ON A/C NOT FOR ALL A. Operational Test of the Underwater Locator Beacon (ULB) with Ultrasonic Test Set (TS200)
Subtask 31-33-00-710-100-A ** ON A/C NOT FOR ALL NOTE: The Ultrasonic Test Set (TS200) is compatible with the DK100, DK120, DK130 and the DK140 ULB.
| ACTION | RESULT |
|---|---|
1.On the DFDR at the ULB:
| On the Ultrasonic Test Set (TS200):
|
2.On the Ultrasonic Test Set (TS200):
|
|
| |
3.On the DFDR at the ULB:
| |
4.On the Ultrasonic Test Set (TS200):
|
|
B. Operational Test of the ULB with the Ultrasonic Test Set (42A12-1)
5. Close-upNOTE: It is not necessary to remove the beacon from its support on the aircraft during this test.
| ACTION | RESULT |
|---|---|
| On the Ultrasonic Test Set: | |
| 1.Turn the GAIN potentiometer to a fully clockwise position. | A background noise must be heard. If no noise is heard replace the battery of the Ultrasonic Test Set. |
| 2.Rub the fingers in front of the microphone. | From speaker you must hear a noise. |
3.On the DFDR at the ULB:
| |
4.On the Ultrasonic Test Set:
| On the Ultrasonic Test Set:
|
Subtask 31-33-00-860-059-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the ULTRASONIC TEST SET:
If you find grease, clean it off with Non Aqueous Cleaner-- Trichlorotrifluoroethane Legacy (Material No.08BBV9) .
(4) Make sure that there are no markings or labels other than the battery replacement label on the ULB.
They can decrease the propagation.
Subtask 31-33-00-410-060-A ** ON A/C NOT FOR ALL (1) On the ULTRASONIC TEST SET:
- Set the TUNING potentiometer to zero.
- Set the GAIN potentiometer to OFF.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(3) Make sure that there is no grease on the support of the ULB and the water switch. If you find grease, clean it off with Non Aqueous Cleaner-- Trichlorotrifluoroethane Legacy (Material No.08BBV9) .
(4) Make sure that there are no markings or labels other than the battery replacement label on the ULB.
They can decrease the propagation.