Optical QAR Software Load Procedure
TASK 31-33-00-710-008-A
Optical QAR Software Load Procedure
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-33-00-861-061-A ** ON A/C NOT FOR ALL Subtask 31-33-00-010-055-A ** ON A/C NOT FOR ALL
Subtask 31-33-00-710-066-C ** ON A/C NOT FOR ALL 5. Close-up
Subtask 31-33-00-710-067-A ** ON A/C NOT FOR ALL Subtask 31-33-00-862-061-A ** ON A/C NOT FOR ALL Subtask 31-33-00-410-054-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.01 00:34:26 UTC
Optical QAR Software Load Procedure
ZONE: 120
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-33-00-710-005-A | Operational Test of the Quick Access Recorder (QAR) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| CMM 313596 |
Subtask 31-33-00-861-061-A ** ON A/C NOT FOR ALL Subtask 31-33-00-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 811.
(2) Open the access door 811. (Ref. AMM TASK 52-41-00-010-002)
Subtask 31-33-00-865-071-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 811.
(2) Open the access door 811. (Ref. AMM TASK 52-41-00-010-002)
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/QAR | 14TU | K17 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
Subtask 31-33-00-710-066-C ** ON A/C NOT FOR ALL 5. Close-up
Subtask 31-33-00-710-067-A ** ON A/C NOT FOR ALL Subtask 31-33-00-862-061-A ** ON A/C NOT FOR ALL Subtask 31-33-00-410-054-A ** ON A/C NOT FOR ALL
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 811. (Ref. AMM TASK 52-41-00-410-002)
(3) Remove the access platform(s).