W DOC AIRBUS | AMM A320F

Operational Test of the Power Interlocks and Status Monitoring


TASK 31-33-00-710-001-A
Operational Test of the Power Interlocks and Status Monitoring


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-008-A
Procedure to Get Access to the SYSTEM REPORT/TEST/INST Page
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
F DFDR-Test ** ON A/C NOT FOR ALL
F DFDR-Test ** ON A/C NOT FOR ALL
F DFDR-Test ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 31-33-00-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) Energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
Subtask 31-33-00-865-050-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CVR/CTL4RKE13
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VURCDR/DFDR7TUK16
** ON A/C NOT FOR ALL
121VUFDIU8TUK17
** ON A/C NOT FOR ALL
121VUAIDS & RCDR/QAR14TUK17
** ON A/C NOT FOR ALL
121VUAIDS & RCDR/FDIMU5TVK15
4. Procedure
Subtask 31-33-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the power interlocks and system monitoring test.
ACTION
RESULT
1.On control panel 21VU:
On control panel 21VU:
  • With the engines stopped press GND/CTL button.
  • Blue light comes on.
2.On MCDU screen 3 CA1:
On MCDU screen 3CA1:
  • Set the MCDU menu.
  • The MCDU menu comes on.
  • Set the CFDS menu on the MCDU menu.
  • The CFDS menu comes on.
  • Set the SYSTEM REPORT/TEST menu on the CFDS menu.
  • The SYSTEM REPORT/TEST comes on.
  • Set the INST menu on the SYSTEM REPORT/TEST menu.
  • The INST menu comes on.
  • Set the FDIU menu on the INST menu.
  • The FDIU menu comes on.
  • Set the GND SCAN menu on the FDIU menu.
  • The GND SCAN menu will come on with a NO FAULT message, or with a fault message showing the equipment at fault and the ATA Ref.
  • Set RETURN on the GND SCAN menu and continue to push RETURN until back to MCDU menu.

3.On control panel 21VU:
On control panel 21VU:
  • Push the GND CTL button.
  • The blue ON legend goes off.
Subtask 31-33-00-710-050-C ** ON A/C NOT FOR ALL
A. Do the Power Interlocks and System Monitoring Test
ACTION
RESULT
1.On the control panel 21VU:
On the control panel 21VU:
  • Push the GND/CTL button.
  • The blue ON legend comes on.
2.On the MCDU 3 CA1:
On the MCDU screen 3CA1:
  • Set the MCDU menu.
  • The MCDU menu shows.
  • Push the line key adjacent to the <CFDS.
  • The CFDS page shows.
  • Push the line key adjacent to the <SYSTEM REPORT/TEST.
  • The SYSTEM REPORT/TEST page shows.
  • Push the line key adjacent to the INST>.
  • The SYSTEM REPORT/TEST INST page shows.
  • Push the line key adjacent to the <FDIU.
  • The DFDRS menu shows.
  • Push the line key adjacent to the <GND SCANNING.
  • The GROUND SCANNING page shows with NO FAULT message or with a fault message showing the equipment at fault and the ATA Ref.
3.On the control panel 21VU:
On the control panel 21VU:
  • Push the GND CTL button.
  • The blue ON legend goes off.
Subtask 31-33-00-710-050-D ** ON A/C NOT FOR ALL
A. Do the Power Interlocks and System Monitoring Test
ACTION
RESULT
1.On the control panel 21VU:
On the control panel 21VU:
  • Push the GND/CTL button.
  • The blue ON legend comes on.
2.On the MCDU 3 CA1:
On the MCDU screen 3CA1:
  • Set the MCDU menu.
  • The MCDU menu shows.
  • Push the line key adjacent to the <CFDS.
  • The CFDS page shows.
  • Push the line key adjacent to the <SYSTEM REPORT/TEST.
  • The SYSTEM REPORT/TEST page shows.
  • Push the line key adjacent to the INST>.
  • The SYSTEM REPORT/TEST INST page shows.
  • Push the line key adjacent to the <DFDRS.
  • The DFDRS menu shows.
  • Push the line key adjacent to the <GND SCANNING.
  • The GROUND SCANNING page shows with NO FAULT message or with a fault message showing the equipment at fault and the ATA Ref.
3.On the control panel 21VU:
On the control panel 21VU:
  • Push the GND CTL button.
  • The blue ON legend goes off.
5. Close-up
Subtask 31-33-00-862-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) De-energize the CFDS (Ref. AMM TASK 31-32-00-860-008).
   (2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:20:26 UTC