Removal of the Centralized Fault Display Interface Unit (CFDIU)
TASK 31-32-34-000-001-A
Removal of the Centralized Fault Display Interface Unit (CFDIU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-32-34-865-050-A
Subtask 31-32-34-020-050-A
[Rev.10 from 2021]
2026.04.01 00:34:07 UTC
Removal of the Centralized Fault Display Interface Unit (CFDIU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 31-32-34-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 31-32-34-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J41 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J40 |
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 31-32-34-020-050-A
A. Removal of the CFDIU
(1) Loosen the nuts (4) on the front of the rack (3).
(2) Lower the nuts (4).
(3) Pull the CFDIU (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the CFDIU (1) from its rack (3).
(5) Put CAP - BLANKING on the electrical connectors (2).
(1) Loosen the nuts (4) on the front of the rack (3).
(2) Lower the nuts (4).
(3) Pull the CFDIU (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the CFDIU (1) from its rack (3).
(5) Put CAP - BLANKING on the electrical connectors (2).
Centralized Fault Display Interface Unit (CFDIU)