Inspection/Check of the Lighted Icing Indicator
TASK 30-81-21-200-001-A
Inspection/Check of the Lighted Icing Indicator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 30-81-21-861-050-A Subtask 30-81-21-941-050-A
Subtask 30-81-21-210-050-A
Subtask 30-81-21-942-050-A
[Rev.10 from 2021]
2026.04.01 00:33:08 UTC
Inspection/Check of the Lighted Icing Indicator
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
FIN: 16DD
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 6M (20 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 30-81-21-000-001-A | Removal of the Lighted Icing Indicator |
| TASK 30-81-21-400-001-A | Installation of the Lighted Icing Indicator |
| (for corrective action) | |
Subtask 30-81-21-861-050-A Subtask 30-81-21-941-050-A
B. Put the ACCESS PLATFORM 6M (20 FT) in position.
Subtask 30-81-21-865-050-A C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H02 |
Subtask 30-81-21-210-050-A
A. Inspection/Check of the Lighted Icing Indicator
(1) On the INT LT section of the overhead control and indicating panel 25VU, set the ICE IND & STBY COMPASS (2LF) switch to ON.
(2) Make sure that the LED of the icing indicator comes on.
(3) If the LED does not come on, do the procedure below:
Subtask 30-81-21-865-061-A (1) On the INT LT section of the overhead control and indicating panel 25VU, set the ICE IND & STBY COMPASS (2LF) switch to ON.
(2) Make sure that the LED of the icing indicator comes on.
(3) If the LED does not come on, do the procedure below:
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-81-21-020-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H02 |
C. Removal of the Lighted Icing Indicator
(1) Release the slotted shroud (1) and remove it.
(2) Remove the transparent cover (2).
(3) Replace the LED (3)ACMM 308112 .
Subtask 30-81-21-420-054-A (1) Release the slotted shroud (1) and remove it.
(2) Remove the transparent cover (2).
(3) Replace the LED (3)
D. Installation of the Lighted Icing Indicator
(1) Install the transparent cover (2).
(2) Install and tighten the slotted shroud (1).
Subtask 30-81-21-865-062-A (1) Install the transparent cover (2).
(2) Install and tighten the slotted shroud (1).
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-81-21-720-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | LIGHTING/STBY/COMP/LIGHT | 1LF | H02 |
F. Test
(1) On the INT LT section of the overhead control and indicating panel 25VU, set the ICE IND & STBY COMPASS switch (2LF) to ON.
(2) Make sure that the LED of the icing indicator comes on.
(a) If the LED does not come on, replace the lighted icing indicator (Ref. AMM TASK 30-81-21-000-001) and (Ref. AMM TASK 30-81-21-400-001).
(3) Set the ICE IND &/STBY COMPASS switch (2LF) to OFF.
5. Close-up(1) On the INT LT section of the overhead control and indicating panel 25VU, set the ICE IND & STBY COMPASS switch (2LF) to ON.
(2) Make sure that the LED of the icing indicator comes on.
(a) If the LED does not come on, replace the lighted icing indicator (Ref. AMM TASK 30-81-21-000-001) and (Ref. AMM TASK 30-81-21-400-001).
(3) Set the ICE IND &/STBY COMPASS switch (2LF) to OFF.
Subtask 30-81-21-942-050-A
A. Remove the access platform(s).
Subtask 30-81-21-862-050-A
Lighted Icing Indicator