Removal of the Valve-Heater


TASK 30-73-56-000-001-A
Removal of the Valve-Heater


WARNING: ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE ENVIRONMENT.
NOTE: The removal procedure is the same for all the heater elements.
FIN: 91DW1 ** ON A/C NOT FOR ALL
FIN: 91DW2 ** ON A/C NOT FOR ALL
FIN: 91DW3 ** ON A/C NOT FOR ALL
FIN: 91DW4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [91DW1] (VALVE-HEATER,)
FOR [91DW2] (VALVE-HEATER,)
FOR [91DW3] (VALVE-HEATER,)
FOR [91DW4] (VALVE-HEATER,)
161DW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 30-73-19-000-001-A
Removal of Temperature Sensor
FOR [91DW1] (VALVE-HEATER,)
FOR [91DW2] (VALVE-HEATER,)
FOR [91DW3] (VALVE-HEATER,)
FOR [91DW4] (VALVE-HEATER,)
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 30-73-56-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
Subtask 30-73-56-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUPOT/WASTE WIP-HEATER-CTL32DWD02
** ON A/C NOT FOR ALL
2001VUPOT/WASTE WIP-HEATER-LINE51DWD04
** ON A/C NOT FOR ALL
2001VUPOT/WASTE WIP HEATER CTL32DWD02
Subtask 30-73-56-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [91DW1] (VALVE-HEATER,), [91DW2] (VALVE-HEATER,), [91DW3] (VALVE-HEATER,), [91DW4] (VALVE-HEATER,)
     (a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001)
     (b) Set the CARGO COMP LT switch 8LU to ON.
     (c) Remove the partition 161DW, (Ref. AMM TASK 25-55-12-000-001).
4. Procedure
Subtask 30-73-56-020-051-A ** ON A/C NOT FOR ALL
A. Removal of Heater Cuff from Fill/ Overflow/ Drain Valve.
   (1) Remove the insulation pack from around the Fill/Overflow/Drain Valve (1)
   (2) Remove and discard the cable ties (4) which attaches the electrical harness (6) of the related heater cuff (3) to the aircraft stringers.
   (3) Disconnect the electrical connections
CAUTION: MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
     (a) Disconnect the electrical connections with the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 from terminal block 7510VT.
   (4) If necessary, remove the related temperature sensor (Ref. AMM TASK 30-73-19-000-001).
   (5) Remove and discard the adhesive tape (2) that attaches the heater cuff (3) to the water pipe (7) adjacent to valve (1).
   (6) Remove the related heater cuff (3).